C
ONTENTS
4.3 U
SING PRODUCT PROFILES
4.3
USING PRODUCT PROFILES

What are product profiles?

4.3.1
Product profiles are memory locations that can store all
the settings for the machine controls. For recurring
production jobs, they allow you to quickly set the
machine to the respective product.
– Number of memory locations: 16
– The memory locations are numbered. In addition,
you can also enter a text identifier for each memory
location (with a maximum of eight alphanumeric
characters).

Loading a product profile

4.3.2
CAUTION!
Incorrect settings may lead to production
problems and damage both the unit and the
equipment.
Only staff who are qualified and specially
trained should set up product databases.
LABEL SETUP > Load prod. profil
Call the
– The following message appears when no memory
location is occupied:
Load prod. profil
No setup avail.
– Only occupied memory locations are displayed.
– When memory locations are occupied, the memory
location that was loaded last is displayed first:
Load prod. profil
Prof 1 xxxxxx
Above example: The profile with the 'xxxxxx' text
identifier has been stored at the first memory
location.
Press the
or the
require appears.
Press the
button to load the profile.
– The unit restarts afterwards.
– Display after the restart:
Prof 1 xxxxxx
Label
(in dispensing mode, 'ONLINE' is replaced by the
current profile name).
function.
button until the profile you
0

Storing a product profile

4.3.3

Selecting the memory location

MACHINE SETUP > Store prod.prof.
Call the
– Display shown when all memory locations are
unoccupied:
Store prod.prof.
Prof 1 Product 1
– When memory locations are already occupied, the
memory location that was last active is displayed:
Store prod.prof.
Prof 5*customer_xyz
– A '*' occurring after the memory location number
indicates that the memory location is already
occupied (here by the 'customer_xyz' profile).
Press the
or the
memory location you require (1–16).
Press the
button to activate the memory
location.
– The profile name flashes, and you can now replace
the name using any text you choose.

Entering profile names

Accepting the profile name 'Product 1' without
changing it:
Press the
button twice.
– The profile is saved.
– Display:
Store prod.prof.
Storing...
Changing a profile name:
Press the
button.
– Display:
Store prod.prof.
Prof x _
– The underscore marks the active position.
Press the
or the
available characters until the character you require
appears.
Press the
button to accept the character.
– The underscore jumps to the next character.
Enter the next character in the same way.
When you have entered the last character, press the
45
ALS
20x
256
GB
function.
button until you retrieve the
button to scroll through the

Hide quick links: