7 - 18 Symbol PL4507 Decoder Integration Guide

Nixdorf Beep/LED Options

Select Nixdorf Mode B to indicate when the decoder beeps and turns on its LED after a decode.
*Normal Operation
(Beep/LED immediately after decode)
Beep/LED After CTS Pulse
Ignore Unknown Characters
Unknown characters are characters the host does not recognize. Select Send Bar Codes with Unknown
Characters to send all bar code data except for unknown characters. The decoder issues no error beeps. Select
Do Not Send Bar Codes With Unknown Characters to send bar code data up to the first unknown character. The
decoder issues an error beep.
*Send Bar Code
(with unknown characters)
Beep/LED After Transmission
Do Not Send Bar Codes
(with unknown characters)