Troubleshooting - Procom QL300RYLA Owner's Operation And Installation Manual

Compact l.p.& natural gas vent-free stove
Table of Contents

Advertisement

WARNING:Make sure that power
is turn off before proceeding....
OBSERVED PROBLEM
No spark when press in ignition button
When pressing the button of ignitor
button is pressed, there is spark at
ODS/pilot but no ignition
ODS/pilot lights but flame is
continuous igniting and the main
burner couldn't be lit.
Burner does not light after ODS/pilot
is lit

TROUBLESHOOTING

WARNING: Turn off and let cool
before servicing. Only a qualified
service person should service and
repair fireplace.
POSSIBLE CAUSE
1. No power to heater
2. No battery in transmitter or battery
isn't correctly assembly
1. Gas supply turned off or equip-
ment shut off valve closed
2. Air in gas lines when installed.
3. Depleted gas supply
4. ODS/pilot is clogged
5. Gas regulator setting is not correct
6. Pilot electrude position is not
correct
7. Wire is not correct or loosen
8 Gas valve is damage
1. Thermocouple connection loose
at control board
2.
Pilot flame not touching
thermcouple which allows thermo-
couple to cool, causing pilot
flame to go out. This problem
could be caused by one or both of
the following
A) Low gas pressure
B) Dirty or partially clogged
ODS/ pilot
3. Thermocouple damaged
4. Control valve damaged
1. Burner orifice clogged
2. Inlet gas pressure is too low
3. Burner orifice diameter is too
small
4. Thermocouple leads discon-
nected or improperly connected
5. Burners will not come in
remote position
1 6
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
REMEDY
1. Check the electric power
2. Place or replace the battery.
1. Turn on gas supply or open
equipment shutoff valve
2
Press ON/OFF button again
2
until air
is removed .
3. Contact
local
propane/LP gas
company
4
Clean
ODS/pilot (see Cleaning
and
Maintenance,page 13 ) or replace
ODS/pilot assembly
Replace gas control
5.
6. Replace Pilot
7.
Check the wine and make wine
correct.
8. Replace gas valve
1. Hand tighten until snug, then
tighten 1/4 turn more.
2. A) Contact local propane/LP gas
company.
B) Clean ODS/pilot (see Cleaning
and Maintenance, page 13) or
replace
ODS/pilot assembly
3.
Replace thermocouple
4.
Replace control valve
1.Clean burner (see Cleaning
and Maintenance, page 13) or
replace burner orifice.
2. Contact
local
propane/LP
gas company
3. Replace burner orifice
4. Reconnect leads (see wiring
diagram)
5. Replace battery in transmitter
and receiver
.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ql300ryla-wQn300rylaQn300ryla-w