Procom QN300TYLA Owner's Operation And Installation Manual

Procom QN300TYLA Owner's Operation And Installation Manual

Compact l.p.& natural gas vent-free stove

Advertisement

OWNER ' S OPERATION AND INSTALLATION MANUAL
QN300TYLA QL300TYLA
QN220TYLA QL220TYLA

Table of Contents

Safety information warnings----------------------2
Installation----------------------------------------------6
Installing Blower Accessory---------------------10
Troubles hooting-------------------------------------15
Parts Breakdown & Parts List------------------18
Log Placing Instructions--------------------------22
WARNING: If the information in this
manual is not followed exactly,a f i r e o r
e x p l o s i o n m a y r e s u l t causing property
damage, personal injury, or loss of life.
WARNING:
This is an unvented gas-
fired heater. It uses air (oxygen) from the
room in which it is installed. Provisions
for adequate combustion and ventilation
air must be provided. Refer to Air For
Combustion and Ventilation section on page
4 of this manual.
CINTINENTAL APPLIANCE INC
5 Musick
Irvine
CA 92618
TOLL-FREE NUMBER: 1-877-886-5989
4600 Highlands Parkway S.E
.
Suite # D/E
Smyrna, GA 30080
COMPACT L.P.& NATURAL
GAS VENT-FREE STOVE
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do
not
touch
use any phone in your building.
Immediately
call
neighbor's phone. Follow the gas supplier's
instructions.
the fire department.
Installation and service must be performed by a
qualified installer, service agency, or local gas
supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause in-
jury or property damage. Refer to this manual for
correct installation and operational procedures. For
assistance or additional information consult a
qualified installer, service agency, or local gas supplier.
This appliance may be installed in an aftermarket*,
permanently located manufactured (mobile) home,
where not prohibited by local codes.This appliance
is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use
with other gases.
WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM
HEATERS
Water vaporis a by-product of gas combustion.An unvented
room heater produces approximately one(1)ounce (30)ml
of water for every 1,000BTU'S (3KW'S) OF gas input per
hour,Refer to papg 6.
Consumer : please retain these instruction for
future use.
Installer:Please leave these instructions with the
consumer.
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
1
any
electrical
switch; do not
your gas supplier from a

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QN300TYLA and is the answer not in the manual?

Questions and answers

Steve Pitts
April 16, 2025

I have a ProCom model QN300TYLA I need a pilot assembly. I found two that look alike one is a 400mm 15 in. the other is a 800mm 32 in. Could you tell me witch one I need? Thank you, Steve

Summary of Contents for Procom QN300TYLA

  • Page 1: Table Of Contents

    Immediately call your gas supplier from a QN300TYLA QL300TYLA neighbor’s phone. Follow the gas supplier’s QN220TYLA QL220TYLA instructions. Table of Contents cannot reach your gas supplier, call the fire department.
  • Page 2: Safety Information Warnings

    SAFETY INFORMATION WARNINGS 4. This heater shall not be installed I M P O R TA N T: R e a d t h i s WARNING: Do not use a blower in a bedroom or bathroom. owner’s manual carefully and insert, heat exchanger insert, or other 5.
  • Page 3: Product Identification

    SAFETY INFORMATION LOCAL CODES UNPACKING Continued lnstall and use heater with care. 1. Remove top inner pack. 15. Turn off and unplug heater and let F o l l o w a l l l o c a l c o d e s . I n t h e 2.
  • Page 4: Air For Conbustion & Ventilation

    AIR FOR COMBUSTION AND VENTILATION Confined and Unconfined Space Unusually Tight Construction WARNING: This heater shall not be installed in a confined space or The National Fuel Gas Code, ANS The air that leaks around doors and unusually tight construction unless Z223.1 defines a confined space as a windows may provide enough fresh provisions are provided for adequate...
  • Page 5 3. Add the Btu/Hr of all fuel burning appliances in the space. Vent-free heater Btu/Hr Example: Gas water heater* Btu/Hr Gas water heater 30,000 Btu/Hr Gas furnace Btu/Hr Vent-free heater + 26,000 Btu/Hr Vented gas heater Btu/Hr Total 56,000 Btu/Hr Gas heater logs Btu/Hr Other gas appliances* +...
  • Page 6: Installation

    INSTALLATION WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is by-product of gas combustion.an unvented room heater prodrces approximately one (1) ounce (30ml) of water for every 1, 000BTU’s (3kw’s) of gas input per hour. Unvented room heaters are recom- mended as supplemtal heat (a room) rather that a primary heat source(an entire house) in most...
  • Page 7: Connecting To Gas Supply

    CLEARANCES TO COMBUSTIBLES The installer must supply an external regulator. (Vent-Free Operation Only) The external regulator will reduce incoming gas Carefully follow the instructions below. pressure. You must reduce incoming gas pres- This stove is a freestanding unit sure to rating inches of water. If you do not reduce designed to set directly on the floor.
  • Page 8: Checking Gas Connections

    Pressure Testing Gas WARNING: Never connect CAUTION: Avoid damage to Supply Piping System heater to private (non-utility) gas regulator. Hold gas regulator with wells. This gas is commonly known wrench when connecting into gas as wellhead gas. Test Pressures In Excess Of 1/2 piping and/or fittings.
  • Page 9 2. Open gas supply tank valve. WARNING: Failure to position It is very important to install the logs 3. Make sure control knob of heater is the parts in accordance with these exactly as instructed. Do not modify in the OFF position. diagrams or failure to use only logs.
  • Page 10: Installing Blower Accessory

    Installing Blower Accessory BLOWER ACCESSORY MODEL PF06-YJLF-F FOR QL300TYLA. QN300TYLA NFHTX186 FOR QL220TYLA. QN220TYLA ACCESSORY PF06-YJLF-F OR 10. Peel off the backing paper and bly to stove by reattaching the NFHTX186 stick the supplied wiring diagram Knock-out center panel to rear...
  • Page 11 Installing Blower Accessory BLOWER ACCESSORY MODEL PF06-YJLF-F OR NFHTX186 Figure 15 -F Routing Power Cord Figure 16 -F Mounting Blower And Installing Blower Control Housing...
  • Page 12: Operating Heater

    LIGHTING OPERATING HEATER INSTRUCTION FOR YOUR SAFETY repairs. Until repairs are made, NOTICE: During initial operation of READ BEFORE LIGHTING light pilot with match. To light new heater, burning logs will give WARNING: If you do not pilot with match, see Manual off a paper-burning smell.
  • Page 13 THERMOSTAT CONTROL CLEANING BURNER OPERATION INJECTOR HOLDER AND The thermostat control knob can be PILOT AIR INLET HOLE set to any comfort level between HI The primary air inlet holes allow the proper amount of air to mix with the and LO.
  • Page 14 . w h e n Weight, pounds contacting your dealer or PRO-COM, Stove 58 lbs. have ready: Shipping 67 lbs. Your name QL300TYLA QN300TYLA Your address Btu(Variable) 20000/30,000BTU/H Model serial numbers Gas Type Propane/LP or NG of your heater...
  • Page 15: Troubleshooting

    TROUBLESHOOTING Note: All troubleshooting CAUTION: Never use a wire, WARNING: Only a qualified items are listed in order of needle, or similar object to service person should ser- operation. clean ODS/pilot. This can vice and repair heater. damage ODS/pilot unit. OBSERVED PROBLEM REMEDY POSSIBLE CAUSE...
  • Page 16 TROUBLESHOOTING Continued POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1. Burner orifice is clogged. 1. Clean burner orifice (see Cleaning Burner(s) does not light after 2. Burner orifice diameter is too and Maintenance) or replace ODS/pilot is lit. small. burner orifice. 3. Inlet gas pressure is too low. 2.
  • Page 17: If You Cannot Reach Your Gas Supplier, Call

    TROUBLESHOOTING Continued WARNING: If you smell gas Shut off gas supply. Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • Page 18: Parts Breakdown & Parts List

    ILLUSTRATED PARTS BREAKDOWN QL300TYLA QN300TYLA QL220TYLA QN220TYLA...
  • Page 19 PARTS LIST QL300TYLA QN300TYLA QL220TYLA QN220TYLA I T P 3 0 - e o l t n u l e n 2 0 - e o l t n u l e n 0 - 5 c a r t e k...
  • Page 20 ILLUSTRATED PARTS BREAKDOWN QL300TYLA QN300TYLA QL220TYLA QN220TYLA...
  • Page 21 PARTS LIST QL300TYLA QN300TYLA QL220TYLA QN220TYLA n r r e n r e r n r e r n r e r n I e P e i...
  • Page 22: Log Placing Instructions

    PLACING INSTRUCTION Follow the procedures below and the instruction drawings to put log sets in place to the gas stove(indoor vent-free). THEN REMOVE SCREEN AND TAKE THE LOG’S PACKAGE IS OUT THE LOG’S PACKAGE LOCATED INSIDE THE UNIT FIRST REMOVE TWO TOP SCREWS FROM SCREEN BOTTOM PANEL NOTICE: THE CORRECT POSITION OF THE LOGS SHOULD NOT IM-...
  • Page 23 Q SERIES LOG SET INSTALLATION INSTRUCTIONS...
  • Page 24 INSTALLATION INSTRUCTIONS FOR LOG SETS 1. All logs FIG(2) FIG(1) STEP 1: Install the log 1 on the left rear angle iron. see FIG(2) FIG(4) FIG(3) STEP 2: Install the log 2 on the right rear angle iron. see FIG(3) STEP 3: Install the log 3 on the front angle iron.
  • Page 25 STEP 4: Insert the pinhole on the upper part of log 4 into the pin on the left side of log 1. Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG(5).

This manual is also suitable for:

Ql300tylaQn220tylaQl220tyla

Table of Contents

Save PDF