Cleaning And Maintenance - Procom QL300RYLA Owner's Operation And Installation Manual

Compact l.p.& natural gas vent-free stove
Table of Contents

Advertisement

3.After completion of the above-
mentioned two steps, the transmitter
is kept in a state of readiness. If the
appliance doesn't working for a
period time, just pull out the plug
from the 110V electrical outlet.
OPERATIONS OF
KEY-PRESS LOCKING
1.Key press locking:
when the burner is in operation or the
transmitter is in a state of readiness,
just press LOCK button on the
operating
panel, there will be a " " symbol on
the LCD. If any button is pressed
now, the burner will not react at all.
2.Key-press unlocking:
when the burner is in a state of key-
press locking, first press ¨‹
press LOCK button to unlock it (Child
proof-See Fig17)
OPERATIONS OF
FAN
There are three selections: "AUTO"
"MAN" and "OFF".When pushing the
"FAN" button on the "AUTO" select,
the fan will be controlled by the
thermostat on the fan blower unit. On
the "MAN" select, the fan will be kept
in operation.To stop the operation,
push the "FAN"button to "OFF"select.
(See Fig17)
INSPECTING BURNERS
C h e c k p i l o t f l a m e p a t t e r n a n d
burner flame patterns often.
PILOT FLAME PATTERN
Figure 18 shows a correct pilot
flame pattern. Figure 19 shows an
incorrect pilot flame pattern. The
incorrect pilot flame is not touching
the thermocouple.This will cause the
thermocouple to cool. When the
thermocouple cools, the heater
will shut down. If pilot flame pattern
is incorrect, as shown in Figure 19.
Turn heater off (see TO TURN
OFF GAS TO APPLIANCE)
see troubleshooting
Figure 18 -Correct Pilot Flame
Pattern
Figure 19 -Incorrect Pilot Flame
Pattern
BURNER FLAME PATTERN
Figure 20 shows a correct burner
flame pattern. Figure 21 shows an
incorrect burner flame pattern. If
burner flame is incorrect:
Turn heater
OFF GAS TO APPLIANCE)
See troubleshooting
, then
¨‹
¨‹
¨‹
¨‹
Figure 20-Correct Flame Pattern
with Control Knob Set to High Flame
Figure 21 -Incorrect Flame Pattern
with Control Knob Set to High Flame
CLEANING AND
MAINTENANCE
WARNING: Disconnect power be-
fore attempting any maintenance or
cleaning to reduce the risk of fire , elec-
tric shook or personal injury. Turn off
heater and let cool before cleaning.
CAUTION:
disconnection
controls
improper and dangerous operation.
Verify proper operation after servicing.
DISCONNECT WIRNG OR CONTROL
MODULE
1. Remove screws from the rear
control panel , take out thermostat
off (see TO TURN
Label all wires prior to
when servicing
.
Wiring errors can cause
1 3
sensing bulb from the clip, then disco-
nnect the wires to free to control
module from its mounting location .
Note: Do not confuse the mark on
the each wire.
2. Remove two screws and hex nuts,
take out the control module. When in-
stalling , reverse the steps above.
(See Figure 22 and Figure 26)
Figure 22- Control Model
DISCONNECT FAN
1.
Remove screws from the fan
bracket panel , pull the fan bracket
panel out to remove. Then disconne-
ct two wires free to fan.
2.
Mark or tag each wire removed
for its exact reconnection. Remove
the four screws from the fan .when
installing , reverse the steps above.
(See Figure 23 and Figure 26)
Figure 23- Fan
CLEANING BURNER INJECTOR
HOLDER AND PILOT AIR INLET HOLE
C A U T I O N : Yo u m u s t k e e p
c o n t r o l a r e a s , b u r n e r , a n d
circulating air passageways of
h e a t e r c l e a n . I n s p e c t t h e s e
a r e a s o f h e a t e r b e f o r e e a c h
u s e . H a v e h e a t e r i n s p e c t e d
yearly by a qualified service person.
H e a t e r
m a y
n e e d
f r e q u e n t
c l e a n i n g
e x c e s s i v e l i n t f r o m c a r p e t i n g ,
bedding material, pet hair, etc.
The primary air inlet holes allow the
proper amount of air to mix with the
gas. This provides a clean burning
flame. Keep these holes clear of dust,
dirt, lint, and pet hair. Clean these air
inlet holes prior to each heating season.
Blocked air holes will create soot. We
recommend that you clean the unit
every three months during operation
and have heater inspected yearly by a
qualified service person.
m o r e
d u e
t o

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ql300ryla-wQn300rylaQn300ryla-w

Table of Contents