2: Description
2.9 Air inlet system, functional
description
The air inlet system consists of two air filters, a compres-
sor air inlet valve and interconnecting piping to the
engine and the compressor.
The air filters are two-stage dry element type filters that
are capable of cleaning extremely dirty air. However,
when operating in dirty environments, the filters should
be checked more frequently.
See Section 5.9.3: Air filter maintenance on page 41 for
air filter maintenance procedures.
2.10 Instrument panel group,
functional description
Refer to Figure 2-4 on page 25 for the locations of the fol-
lowing indicators and controls:
• The air pressure gauge continuously monitors
the sump pressure under various load condi-
tions.
• The engine switch energizes the system and
starts the compressor. The engine switch is
pressed to the ON position to energize the
electrical system, and pressed momentarily to
the START position to engage the starter and
start the compressor.
• The idle warm-up control is turned from START
to RUN after sufficient warm-up is achieved for
full compressor operation.
• The shutdown indicator light indicates engine
and compressor safety shutdown status.
24
02250223-054 R01
Subject to EAR, ECCN EAR99 and related export control restrictions.
185 T3 Kubota User Manual
• The hourmeter indicates the accumulated
hours of operation.
• The cold weather starting aid glow plugs should
be used for starting in cold weather. Press the
button and hold for 10 – 30 seconds (depend-
ing upon ambient temperature). Release the
button prior to starting.
• The optional engine voltage gauge monitors
the voltage level of the engine storage battery.
• The optional engine coolant temperature gauge
monitors the temperature of the engine coolant
in the engine.
• The optional tachometer monitors the operating
speed of the engine.
• The optional fuel level gauge indicates the fluid
level in the fuel tank.
• The optional compressor discharge tempera-
ture gauge monitors the temperature of the air/
oil mixture in the sump.
WARNING
Do not use aerosol types of starting aids such
as ether. Such use could result in an explosion
and personal injury.
NOTICE
If the engine fails to start within 30 seconds, wait
two minutes to allow the starting motor to cool
before attempting to start the engine again.