Migration Has Failed With "Transferring Device Data Cannot Be Completed Within An Lpar Suspension Period." Message - Hitachi NVM Navigator v03-07 User Manual

Migration manual
Table of Contents

Advertisement

Migration has failed with "Transferring device data cannot be
completed within an LPAR suspension period." message
Event
LPAR migration has failed with "Transferring device data cannot be completed
within an LPAR suspension period."
This error occurs because a migrated LPAR cannot boot on the destination
server blade within LPAR suspension time.
Figure 6-21 Migration Progress window
Solution
Execute the LPAR migration again. When the LPAR migration fails though you
attempt to the LPAR migration several times, reduce the memory load as
much as possible on the guest OS on the LPAR to migrate.
6-20
Troubleshooting
HVM Navigator User's Guide - Migration

Advertisement

Table of Contents
loading

Table of Contents