Hitachi NVM Navigator v03-07 User Manual page 21

Migration manual
Table of Contents

Advertisement

Grouping
Setting
-: No case
1
You cannot change the setting on HVM firmware version 58-2x/78-2x or earlier, or 17-4x or
earlier. Whereas, you can change the setting on HVM firmware version 58-4x/78-4x or higher, 17-
61 or earlier, any HVM firmware version for CB500, or any HVM firmware versions for CB2500.
2
The value of the item isn't transferred to the destination server blade and is set to 'A' on
destination server blade when the Guest NUMA feature is disabled, whereas, when the Guest NUMA
feature is enabled, it is transferred to the destination server blade.
3
You can change the setting. However, do not specify any LPAR, with shared NICs of which logical
MAC addresses you have changed manually, as the source or destination LPAR.
4
You can change the setting through only HvmSh.
HVM Navigator User's Guide - Migration
Item
CA certificate
Security strength
Verify certificate
Overview
Migration to destination
Setting
Shutdown
4
No
4
No
4
No
Concurrent
Maintenance
1-7

Advertisement

Table of Contents
loading