CB500
When you execute LPAR migration in Shutdown mode between HVM firmware
01-30 or earlier and 01-40 or higher, and the VNIC System No. set for the
HVM firmware 01-40 or higher is 129 or greater, you cannot execute LPAR
migration in Shutdown mode. Confirm the combinations of the source and
destination between which you can execute LPAR migration in Shutdown mode
in the following table.
Table 2-120 LPAR migration on HVMs on CB 500 server blades
Source
HVM firmware version
01-30 or earlier
01-40 or higher
HVM Navigator User's Guide - Migration
Destination
01-30 or earlier
VNIC System No.
128 or smaller
128 or smaller
128 or smaller
129 or greater
Usage environments
Concurrent Maintenance
HVM firmware version
01-40 or higher
128 or smaller
Yes
Yes
Yes
Yes
No
Yes
129 or greater
No
Yes
Yes
2-67