Download Print this page

Ordering Information - Keysight Technologies N9320A RF Configuration Manual

Spectrum analyzer

Advertisement

02 | Keysight | N9320B RF Spectrum Analyzer – Configuration Guide
Configure Your Keysight N9320A RF Spectrum Analyzer
The Keysight Technologies, Inc. N9320B is a general purpose
spectrum analyzer from 9 kHz to 3 GHz. Its standard features
include:
– Frequency power measurements
– One-button power suite, auto tune, and frequency counter
– AM/FM tune and listen
– 12 markers, 4 traces, and 2 customer-definable limit lines
– U2000 Series USB power sensor support
– USB and LAN connectivity

Ordering information

Description
RF spectrum analyzer, 9 kHz to 3.0 GHz
Description
Step 1. Add a preamplifier
Preamplifier, 3.0 GHz
Step 2. Add modulation analysis capability
AM and FM demodulation metrics
ASK and FSK demodulation metrics
1. Signal-to-noise and distortion ratio
Step 3. Add scalar stimulus-response measurement capability
Tracking generator, 100 kHz to 3.0 GHz
Step 4. Add optional features
Resolution bandwidth (–6 dB):
200 Hz, 9 kHz, 120 kHz, and 1 MHz
GPIB interface
Customized save-last utility
Instrument power-on utility at AC power cycle
This step-by-step process will help you to configure your
N9320B RF spectrum analyzer by tailoring its options to meet
your requirements.
For detailed specifications, refer to the N9320B spectrum analyzer
data sheet (5990-8119EN). For a product overview, refer to the
N9320B spectrum analyzer brochure (5990-8118EN).
Model number
Additional information
N9320B
Accessories supplied as standard with each analyzer: Quick Start Guide,
USB cable, N-BNC adapter, BNC cable, power cord, and documentation
CD-ROM
Option number
Additional information
N9320B-PA3
Preamplifier improves the noise floor for low-level signal detection
N9320B-AMA
Provides modulation metrics of an AM or FM signal: Carrier power,
modulation rate, AM depth, frequency deviation, SINAD
frequency offset
N9320B-DMA
Provides modulation metrics of an ASK or FSK signal: Carrier power,
ASK error, depth, and index, FSK deviation, FSK error, magnitude error,
and carrier frequency offset
N9320B-TG3
A cost-effective method to measure transmission characters of RF
devices. An external bridge or a directional coupler needs to be added to
implement reflection measurements
N9320B-EMF
Provides optional CISPR16-1-1 EMI filters for preliminary EMI
pre-compliance measurements
N9320B-G01
IEEE-488 bus connector, used in test automation systems
N9320B-C20
N9320B automatically saves its settings and status once any changes are
made. After the power cycle, the N9320B recovers the prior setups before
powering off
N9320B-C30
N9320B powers on directly at AC power cycle without the user pushing
the power-on button on the unit's front panel. A solution designed for test
automation systems
1
, and carrier

Advertisement

loading

This manual is also suitable for:

N9320b rf