Ethernet / DMX operation
Option " Artnet" (gMaI or gMA2 or sACN) has to be selected from "Ethernet Mode" menu at first fixture.
Option "Ethernet To DMX" has to be selected from the menu "Ethernet Mode" at the first fixture (connected to
the Ethernet) in the fixture chain, next fixtures have standard DMX setting.
Connect the Ethernet input of the first fixture in the data chain with the network. Connect DMX output of this
fixture with DMX input of the next fixture until all fixtures are connected to the DMX chain.
Caution: At the last fixture, the DMX chain has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last fixture.
Example:
DMX address=236
DMX address=236
DMX address=196
DMX address=196
14
DMX address=1
IP addres=002.168.002.002
Universe=0
DMX address=1
IP addres=002.168.002.003
Universe=1
Ω
resistor