ZXR10 ZSR V2 Hardware Description
6.1.3 System Parameters
For system parameters of a ZXR10 1800-2E router, refer to
Table 6-3 System Parameters of a ZXR10 1800-2E Chassis
Item
Physical Parameters
Storage capacity
Slot
DC power (single)
AC power (single)
Grounding resistance
6.2 Power Supplies
ZXR10 ZSR V2 serial routers support a voltage within the range of 100 V–240 V, AC power
of 50 Hz–60 Hz, and DC power from -38 V to -72 V. The 1+1 dual-power redundancy mode
and power supply swapping are available.
The power modules have the following functions:
l
Alarms are generated due to a high or low input or output voltage.
SJ-20150204153047-004|2015-03-30 (R1.0)
Dimension (width × height ×
depth)
Weight (with full
configuration)
Maximum power
consumption
Memory
FLASH
Number of slots
Number of slots for line
interface boards
Redundancy backup
Rated output power
Rated input voltage
Range of the maximum input
voltage
Redundancy backup
Rated input voltage
Range of the input frequency
Rated output power
6-4
Table
6-3.
Physical Parameters
17.41 in. × 1.73 in. × 17.32 in. (442 mm ×44
mm ×440 mm)
< 19.0 lb. (8.6 kg)
< 80 W
2 GB
1 GB
4
2
1+1 redundancy backup, supporting both AC
and DC
250 W
From -60 V DC to -48 V DC
From -72 V DC to -38 V DC
1+1 redundancy backup, supporting both AC
and DC
100 V AC–240 V AC
50 Hz–60 Hz
250 W
Grounding resistance with common earthing,
which is lower than 5 Ω
ZTE Proprietary and Confidential