External Voltage
3.3V
5V
12V
24V

3.10.3 Line2 Configurable Bi-direction I/O Circuit

In controlling I/O, the configurable bi-direction non-isolated IO circuit of Line2 can
be shown in Figure 3-56.
Note:
The camera of MV-CA030-10GM/GC has no such function.
1. Configure Line2 to input pin
Logic 0 input level: 0~0.5VDC (GPIO2 pin)
Logic 1 input level: 1.5~30VDC (GPIO2 pin)
Please make sure the input voltage is not from 0.5V to 1.5V as the electric status
among the two values is not stable.
User Manual of Area Scan GigE Camera
Table 3-6 The Parameter of Output Logic Low Level
External Resistor
1KΩ
1KΩ
2.4KΩ
4.7KΩ
Figure 3-56 Line2 Bi-direction I/O Circuit
VL
Output Current
575mV
2.7mA
840mV
4.1mA
915mV
4.6mA
975mV
4.9mA