3.9 Imaging Parameter Setting

3.9.1 Exposure Time

Please refer to the camera technical index to acquire the supported exposure time. The
exposure control supports manual mode, single mode and continuous mode. When
setting trigger mode, the single mode and continuous mode are invalid. When setting
single mode or continuous mode, the exposure time will be limited by Auto Exposure
Time Lower Limit and Auto Exposure Time Upper Limit. The time range should only
be set between Auto Exposure Time Lower Limit and Auto Exposure Time Upper
Limit.
Click Acquisition Control in the attribute list. Select Auto Exposure Time Lower
Limit and Auto Exposure Time Upper Limit. Input available parameter to the numeric
field. Set the running parameter range of the auto exposure time, as shown in Figure
3-36.

3.9.2 Gain Control

Please refer to the camera technical index to acquire the supported Gain Value. Gain
Control supports manual mode, single mode and continuous mode. Gain Control
under these three modes can be shown as follows:
Manual mode: Set Gain according to the user's setting value.
Single mode: Set Gain value automatically according to the target image brightness.
Set once only.