HIKVISION DS-7204HQHI-K1 User Manual

HIKVISION DS-7204HQHI-K1 User Manual

Power over coaxial
Hide thumbs Also See for DS-7204HQHI-K1:

Advertisement

User Manual of Storage Prod and Solution
PoC (Power over Coaxial)
White Paper
0

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION DS-7204HQHI-K1

  • Page 1 User Manual of Storage Prod and Solution PoC (Power over Coaxial) White Paper...
  • Page 2 INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
  • Page 3 SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
  • Page 4: Table Of Contents

    User Manual of Storage Prod and Solution Contents CHAPTER 1 OVERVIEW ....................... 4 CHAPTER 2 POC AND ANALOG SURVEILLANCE WIRING ............5 CHAPTER 3 THE BASICS OF POC ..................7 ......................7 AMERA ONNECTION ..................7 AMERA OWER UPPLY CENARIOS ......................
  • Page 5: Chapter 1 Overview

    Chapter 1 Overview From 2017, Hikvision released Turbo 4.0 DVR products. It is a big technical improvement from previous ones and the function of PoC (Power Over Coaxial) is a highlight. In this white paper, the theory of PoC, as well as its application and possible exceptions, will be explained.
  • Page 6: Poc And Analog Surveillance Wiring

    DC current-based video signals. The technical barrier of PoC module is how to overlap DC current and video signals without causing interference to video signals. The patented technology of Hikvision effectively separates AC and DC current so that electricity and video signals are transmitted harmoniously together on coaxial cables.
  • Page 7 White Paper of Power over Coaxial (PoC) Figure 2-2 PoC 1.0 Wiring PoC 2.0 wiring: The cameras are connected to DVR through a coaxial cable that transmits video signals, control signals and power supply. Figure 2-3 PoC 2.0 Wiring...
  • Page 8: Chapter 3 The Basics Of Poc

    Figure 3-1 Camera Connection  Only Hikvision PoC camera can be connected to a PoC DVR. A self-powered PoC camera can be connected to a non-PoC DVR.  Turn off the PoC power supply function of the DVR before connecting to a non-PoC camera.
  • Page 9: Dual-Power Supply

    12 VDC power. 3.4 AT/AF Mode With reference to PoE standards, Hikvision has introduced AT and AF mode for PoC to distinguish the power level of PoC cameras: the max. operating power of AT and AF are 10 W and 6 W respectively.
  • Page 10: Camera Access Time

    White Paper of Power over Coaxial (PoC) Figure 3-2 Insufficient Power For PoC 3.7 Camera Access Time Time to access single channel PoC camera: approx. 30 sec Time to access multiple channel PoC camera: within 1 min...
  • Page 11: Chapter 4 Poc Connection And Transmission Distance

    White Paper of Power over Coaxial (PoC) Chapter 4 PoC Connection and Transmission Distance 4.1 Connection Method  Use BNC cable 4.2 Transmission Distance Transmission distance is related to cable material and power of the connected PoC camera. Details are listed below. PoC AF Camera PoC AT Camera PoC AF Camera...
  • Page 12: Poc Device Model

    White Paper of Power over Coaxial (PoC) Chapter 5 PoC Device Model 5.1.1 DVR  Models for access of 2 MP PoC cameras: DS-7204HQHI-K1/P, DS-7208HQHI-K2/P, DS- 7216HQHI-K2/P.  Models for access of 4 MP PoC cameras: DS-7204HUHI-K1/P, DS-7208HUHI-K2/P, DS- 7216HUHI-K2/P.
  • Page 13: Gui, Exception And Log Of Poc Dvr

     You can click the channels in Poc Channel to turn on/off the PoC power supply. Turn on the PoC power supply only when the DVR connects to Hikvision PoC camera, otherwise please turn off the PoC power supply. ...
  • Page 14: Log

    White Paper of Power over Coaxial (PoC) Figure 6-2 Exception Configuration You can also configure different linked actions for PoC exception. 6.3 Log Three types of exceptions will be recorded in the logs:  PoC module communication exception Possible cause: Communication exception between PoC module and motherboard. ...
  • Page 15 White Paper of Power over Coaxial (PoC) Figure 6-3 Log Information...
  • Page 16: Poc Safety Features

    White Paper of Power over Coaxial (PoC) Chapter 7 PoC Safety Features The safety features of PoC include: 1. Overcurrent protection. The PoC system monitors the output current in real-time and will cut off power output to protect the system in case of overcurrent. 2.
  • Page 17 White Paper of Power over Coaxial (PoC)

Table of Contents