POST error codes

The following table describes the POST error codes and suggested actions to
correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3400 Types 7973, 7974, 7975 and 7976," on page 87 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
062
Three consecutive boot failures using the
default configuration.
101
Tick timer internal interrupt failure.
102
Internal timer channel 2 test failure.
151
Real-time clock error.
161
Real-time clock battery failure.
162
Invalid configuration information or CMOS
random-access memory (RAM) checksum
failure.
24
System x3400 Types 7973, 7974, 7975, and 7976: Problem Determination and Service Guide
Action
1. Update the system firmware to the latest level
(see "Updating the firmware" on page 165).
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
1. Reseat the battery.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Reseat the battery.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Run the Configuration/Setup Utility program,
select Load Default Settings, and save the
settings.
2. Reseat the following components:
a. Battery
b. Failing device (If the device is a FRU, it must
be reseated by a trained service technician
only.)
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (If the device is a FRU, it must
be replaced by a trained service technician
only.)
c. (Trained service technician only) System
board