3. self-diagnosis of controller unit

3-1 Purpose

The error diagnosis of the meter is possible by using the self-diagnostic harness. The self-diagnostic
function of a conventional model provided with a microcontroller can detect failures in the microcontroller
only after all the failure diagnosis of the electrical devices other than the microcontroller is made. This
kind of method requires time. Furthermore, there is a fear in the accuracy of the diagnosis.
By connecting the self-diagnostic harness to the meter and applying voltage from the battery, the self-
diagnostic program built into the meter will run, thus making the self-diagnosis of the incorporated hard-
ware of the meter possible with the inputs and outputs of the meter automatically activated and checked.
Note:
It is not 100% possible to make the perfect self-diagnosis of the hardware of the meter, however,
because not all hardware components built into the meter are checked.

3-2 Operation Procedure

1. Dismount the meter from the main harness of
the equipment and connect the meter to the
self-diagnostic harness.
2. Connect the 12-V terminal and negative termi-
nal of the self-diagnostic harness to the battery.
3. Self-diagnosis starts automatically.