Kubota KX71-3 Workshop Manual page 124

Hide thumbs Also See for KX71-3:
Table of Contents

Advertisement

KX61-3, KX71-3 WSM-M
Address No.
65
3 Charge
66
2 Engine oil
67
4 High voltage
68
11 Accel sensor
69
13 AI motor short
70
14 AI motor break
71
12 Governor sensor
72
21 Aux.volume
73
22 Aux.solenoid L short
74
23 Aux.solenoid L break
75
24 Aux.solenoid R short
76
25 Aux.solenoid R break
77
5 Overheat
78
55 Meter controller error
79
54 Sensor supply short 5V
80
53 Sensor supply short 12V
81
52 Fuel sensor
82
51 Coolant sensor
83
61 AI motor retricted
84
85
3 Charge
86
2 Engine oil
87
4 High voltage
88
11 Accel sensor
89
13 AI motor short
90
14 AI motor break
91
12 Governor sensor
92
21 Aux.volume
93
22 Aux.solenoid L short
94
23 Aux.solenoid L break
95
24 Aux.solenoid R short
96
25 Aux.solenoid R break
97
5 Overheat
98
55 Meter controller error
99
54 Sensor supply short 5V
100
53 Sensor supply short 12V
101
52 Fuel sensor
102
51 Coolant sensor
103
61 AI motor retricted
Contents of failure
Fig.3 EEPROM Addresses for Error Log
M-V-38
Data bit
The leftmost 12 bits display the hour meter value of
the last error. The rightmost four bits display the
accumulated number of errors.
reserve
The leftmost 12 bits display the hour meter value of
the last error. The rightmost four bits are dummy bits.