Fuel Amount Control; Circuit Diagram & Function (Fuel Sensor); Voltage And Fuel Map; Fuel Shortage Alarm - Kubota KX71-3 Workshop Manual

Hide thumbs Also See for KX71-3:
Table of Contents

Advertisement

KX61-3, KX71-3 WSM-M

3-18 Fuel amount control

1. Outline
A map indicating the voltage and fuel relationship has been prepared by plotting each determined input
voltage based on the float position of the fuel sensor and the remaining fuel.
The power supply voltage (5V) is input into the microcomputer according to the partial voltage varied
with the float position. Therefore, when calculating the actual quantity of remaining fuel, make a map
conversion with consideration of the power supply voltage.
The fuel shortage alarm will be displayed when the quantity of remaining fuel is between approximately 5
and 10 liters, the range of which, however, varies with the model. As a rule of thumb, the fuel will last for
approximately one hour after the alarm turns ON.
Circuit diagram & function(Fuel sensor)
(1)Fuel sensor (2)Water temp sensor (3)Meter (4)AD voltage
(Calculation example) Voltage value is 0.899 for example.
Theoretically, water sensor's resistance is 179.76 Ω

Voltage and fuel map

M-V-24
Electrical System

Fuel shortage alarm

Fuel residual
Model
amount [l]
KX41-3
5 ± 3
KX61-3
7 ± 3
KX71-3
7 ± 3
(Water temp sensor)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx61-3

Table of Contents