6 | Keysight | PNA Family Microwave Network Analyzers - Configurations Guide
PNA Family Network Analyzer Configurations
PNA-X Series
N5249A 10 MHz to 8.5 GHz
N5241A 10 MHz to 13.5 GHz
N5242A 10 MHz to 26.5 GHz
N5244A 10 MHz to 43.5 GHz
N5245A 10 MHz to 50 GHz
N5247A 10 MHz to 67 GHz

Application options

To add options to a product, order the corresponding item number (N52xxA-xxx).
Measurement application
Automatic fixture removal
Time-domain measurements
Noise figure measurements using standard
receivers
1
Fully-corrected noise figure
measurements
1
Frequency offset
2
Scalar-calibrated converter measurements3
Vector- and scalar-calibrated converter
measurements
3, 4
Embedded LO measurements
Gain compression application
Intermodulation distortion
application
5
Source phase control
Differential and I/Q devices application
Spectrum analyzer
Integrated true-mode stimulus application
N-port capabilities
6
1
For N522xA and N5241/42/49A, vector-noise-corrected measurements require an ECal for use as an impedance tuner. For N5244/45/47A with Option 029,
an internal tuner is included. For calibration, Option 028 requires a power meter, and Option 029 requires either a power meter or a 346-series noise source
(Keysight 346C or 346C-K01 recommended). All options require a power meter for measuring mixers and converters.
2
Option 080 is required to configure an external source using External Device Configuration dialog.
3
Option 082 is a subset of Option 083; therefore, they cannot be ordered together.
4
A configurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-based
calibration. When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with a
calibration mixer.
5
Option 087 can be ordered without N524xA-224 or N524xA-423, but may require external equipment such as a signal generator and a combiner. Refer to
page 13 for more details.
6
When ordering a test set, select an appropriate interface kit. Refer to page 22 Multiport Measurements section for more details.
7
When configuring N524xA as a multiport analyzer using Option 551 and a multiport test set, the combiner feature of Option 224 or 423 is temporarily
disabled. When configuring N524xA as a standalone analyzer, the combiner feature is enabled.
8
The Windows 7 upgrade kit is model N8983A. This upgrade kit contains a new disk drive and requires an i7 or Celeron CPU. For units with older CPUs, order
Option PC6 for a new i7 CPU. For adding Option 090 to units with an older CPU, order Options PC6 and SP5.
PNA Series
N5221A 10 MHz to 13.5 GHz
N5222A 10 MHz to 26.5 GHz
N5224A 10 MHz to 43.5 GHz
N5225A 10 MHz to 50 GHz
N5227A 10 MHz to 67 GHz
For PNA-X Series
For PNA Series
N524xA-007
N522xA-007
N524xA-010
N522xA-010
N524xA-028
N522xA-028
N524xA-029
n/a
N524xA-080
N522xA-080
N524xA-082
N522xA-082
N524xA-083
N522xA-083
N524xA-084
N522xA-084
N524xA-086
N522xA-086
N524xA-087
N522xA-087
N524xA-088
N522xA-088
N524xA-089
N522xA-089
N524xA-090
N522xA-090
N524xA-460
N522xA-460
N524xA-551
N522xA-551
7
(continued)
PNA-L Series
N5239A 300 kHz to 8.5 GHz
N5231A 300 kHz to 13.5 GHz
N5232A 300 kHz to 20 GHz
N5234A 10 MHz to 43.5 GHz
N5235A 10 MHz to 50 GHz
For PNA-L
Series
Additional Information
N523xA-007
Requires Windows 7 OS
N523xA-010
n/a
Requires Option 080. For measuring frequency converters,
requires Option 082 or 083. Not available with N522xA-200,
-210, -400 and -410
n/a
Requires Option 080 and for N5241/42/49A, one of Options 219,
224, 419, 423 or H85. For N5244/45/47A, requires Option 224
or 423. On N5247A, noise receivers work up to 50 GHz only. For
measuring frequency converters, requires Option 082 or 083.
N523xA-080
N523xA-082
Requires Option 080
n/a
Requires Option 080
n/a
Requires Option 082 or Option 083. Also works with Options
028, 029, 086 and 087
n/a
For measuring frequency converters, requires Option 082 or 083
n/a
Requires Option 080 For measuring frequency converters,
requires Option 082 or 083. Not available with N522xA-200,
-210, -400 and -410
n/a
Not available with N522xA-200 and -210
n/a
Requires Option 080 and 400, 401, 410, 417, or 419, and
Windows 7 OS
8
n/a
Requires Option 080, Windows 7 OS, and DSP version 5
set and power configuration option with receiver attenuators is
recommended.
n/a
Requires one of Options 400, 401, 410, 417, 419 or 423
N523xA-551
Not available with N522xA-200, -210, -400 and -410, and
N523xA-200 and -400
8