22 | Keysight | PNA Family Microwave Network Analyzers - Configurations Guide
PNA Family Network Analyzer Upgrade Kits

Application options

Upgrade kits are available to add options after initial purchase. To upgrade the PNA-X/PNA/PNA-L, order the corresponding
item number. The model and serial numbers of the instrument to be retrofitted are required as part of the order.
Description
Measurement applications
Automatic fixture removal
Time-domain measurements
Noise figure measurements using standard receivers
Fully-corrected noise figure measurements
for PNA-X, 2-ports
Fully-corrected noise figure measurements
for PNA-X, 4-ports
Frequency offset
Scalar-calibrated converter measurements
Vector- and scalar-calibrated converter measurements
Embedded LO measurements
Gain compression application
Intermodulation distortion application
Source phase control
Differential and I/Q devices application
Spectrum analyzer
Integrated true-mode stimulus application
N-port capabilities
Pulse, antenna, mm-wave
Pulsed-RF measurements
Add IF inputs
Add pulse modulator to internal 1st source
Add pulse modulator to internal 2nd source
Add four internal pulse generators
Fast CW sweep
1
For measuring frequency converters, Option 082 or 083 is required.
2
Requires configurable test set for signal conditioning of noise figure measurements using standard receivers. Therefore it is not available with
-400 and -410.
3
Upgrading N5244A units with noise figure hardware requires serial-number prefixes of 5204 or higher, and upgrading N5245A units requires serial-number prefixes of
5205 or higher. For these two models, units with lower serial-number prefixes can be traded in for credit towards a new unit with the noise figure hardware.
4
Two-tone signal must be routed to R1 receiver after an external combiner; therefore it is not available with N522xA-200, -210, -400 and -410.
5
When used with an external signal generator, configurable test set is required to access a receiver. Therefore it is not available with N522xA-200 and -210.
6
To connect a multiport test set, configurable test set is required. Therefore it is not available with N522xA-200, -210, -400, -410, and N523xA-200, and -400.
7
The Windows 7 upgrade kit is model N8983A. This upgrade kit contains a new disk drive and requires an i7 or Celeron CPU. For units with older CPUs, order Option
PC6 for a new i7 CPU. When adding Option 090 on units with an older CPU, order Options PC6 and SP5.
8
A configurable test set is required for VMC measurements (to connect a reference mixer) or for SMC+Phase measurements using the comb-generator-based calibra-
tion. When ordered with N522xA-200, -210, -400 and -410, Option 083 adds phase and delay measurements only by using SMC+Phase with a calibration mixer.
9
Optional receiver attenuators are recommended to avoid receiver compression for large-scale measurements.
Required Option
7
Windows 7 OS
.
Option 080
1,2
Option 080 and for N5241/42/49A, one of Op-
tions 219, 224 or H85
.
1
For N5244/45/47A, 080 and 224
Option 080 and for N5241/42/49A, one of Op-
tions 419, 423 or H85
.
1
For N5244/45/47A, 080 and 423
Option 080
Option 080
8
Option 082 or 083
See Footnote 1
Option 080
1,4
See Footnote 5
Option 080 and 400, 401, 410, 417, or 419, and
Windows 7 OS
7
Option 080, Windows 7 OS, and
DSP version 5
7, 9
Option 400, 401, 417, 419, or 423
See Footnote 6
Option 025
1
Option 224, 400, 401, 417, 419, or 423
(continued)
For PNA-X
For PNA
Series
Series
N524xAU-007
N522xAU-007
N524xAU-010
N522xAU-010
N524xAU-028
N522xAU-028
N524xAU-924
n/a
3
N524xAU-929
n/a
3
N524xAU-080
N522xAU-080
N524xAU-082
N522xAU-082
N524xAU-083
N522xAU-083
N524xAU-084
N522xAU-084
N524xAU-086
N522xAU-086
N524xAU-087
N522xAU-087
N524xAU-088
N522xAU-088
N524xAU-089
N522xAU-089
N524xAU-090
N522xAU-090
N524xAU-460
N522xAU-460
N524xAU-551
N522xAU-551
N524xAU-008
N522xAU-008
N524xAU-020
N522xAU-020
N524xAU-021
N522xAU-021
N524xAU-022
N522xAU-022
N524xAU-025
N522xAU-025
N524xAU-118
N522xAU-118
For PNA-L
User
Series
Installable
N523xAU-007
Yes
N523xAU-010
Yes
n/a
Yes
n/a
No
n/a
No
N523xAU-080
Yes
N523xAU-082
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
N523xAU-551
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
n/a
Yes
N522xA-200, -210,

Advertisement

Table of Contents
loading