Pin
Description
47
Data out Hi – Diagnostics output
48
RS232 #2 Hi – Messenger output
49
Data in Hi – Diagnostics input
50
RS232 #2 Hi – Messenger input
51
PC S RX (Data Connections only)
52
RS232 #1 Hi – Serial G.P.S. input
53
Program-md1-- Factory Use Do Not
Connect
54
Program-RST-- Factory Use Do Not
Connect
55
Event switch #8 – Gnd=Active,
configuration. switch style
(mom,alt,dial,sqt)
56
Event switch #7 – same as pin 55
57
Event switch #6 – same as pin 55
58
Event switch #5 – same as pin 55
59
Event switch #4 – same as pin 55
60
Event switch #3 – same as pin 55
61
Event switch #2 – same as pin 55
62
11-33VDC positive voltage input
View of connector from rear (side contacts insert in)
Flow
Out
Out
In
In
In
In
In
In
In
In
In
In
In
In
Figure 2
3 - 11
1616-964-12
Date: 7/27/2011