Real-Time Clock Battery; Hard Disk Drive - Valueline VL PPC 6015 VW 10 User Manual

Ipc with touch screen
Table of Contents

Advertisement

2637_en_D
4.1.1

Real-time clock battery

There is a battery located under the access door. This battery supplies power to the Real-
Time Clock (RTC) in the VL IPC when the system is not connected to a 24 V DC power
source. The battery has a typical life of 5 years and requires replacement occasionally.
To replace the battery
1.
Open the access door at the rear of the IPC module.
2.
The RTC battery is above the hard disk slot. Use a needle nose pliers to carefully pull
out the battery.
3.
Be sure to replace the battery with the same type (CR2032 3V Lithium), oriented as
shown in Figure 4-4.
R :
W E
P O
H
E T
X 2
H
E T
X 3
Figure 4-4
Insert RTC battery as shown
4.1.2

Hard disk drive

The hard drive installs in a tray that is easily removable. VL IPC systems without a hard drive
come with a blank tray. To install a new hard drive or replace the current hard drive, follow
these instructions:
1.
Remove power from the unit.
If necessary, move or disconnect any cables that interfere with accessing the hard drive.
2.
Open the access door.
3.
Turn the screw counterclockwise several turns. It is spring-loaded and, when it clears
the threads, it pops out.
4.
Grasp the screw and swing the front lever out from the door.
B
A
+
C
V D
2 4
Positive (+)
CR2032 3V Lithium battery
PHOENIX CONTACT
Maintenance
4-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2913181

Table of Contents