3.8.1

Power supply recommendations

The Valueline IPC requires a 24 V DC power source. This can be either a standard power
supply or a DC UPS. The following table provides expected amperage requirements for
different configurations.
Table 3-2
Power requirements
Processor
Atom
Celeron and Core2 Duo
Any configuration with PCI slots
1
The 24-in. display requires an additional power connection
3.8.2
QUINT-DC-UPS... installation
When using the QUINT-DC-UPS... uninterruptable power supply, there are two ways to
connect it to the Valueline IPC depending upon the level of monitoring/control desired.
Power connector: This connection method allows monitoring of the Bat.-Mode signal
via two terminals labeled A and B on the power connector. When the uninterruptable
power supply switches to battery power, it closes a contact to activate the Bat.-Mode
signal. The operating system starts the "Minutes on battery before critical alarm" timer,
if it is configured by the user (see Figure 3-39). If it is not configured, the operating
system starts the Critical Alarm timer which gives 30 seconds to launch and execute an
optional program before the VL IPC initiates the shutdown procedure.
Any program launched at this time is typically used to send an alert message to a system
administrator that the computer is shutting down. This program must reside in
C:\Windows\system32.
Serial port (DB-9): This connection method provides additional communication
between the Valueline IPC and the uninterruptable power supply.
As in the power connection method, when the un interruptible power supply
switches to battery power, it closes a contact to activate the Bat.-Mode signal. The
operating system starts the "Minutes on battery before critical alarm" timer, if it is
configured by the user (see Figure 3-39). If it is not configured, the operating
system starts the Critical Alarm timer which gives 30 seconds to launch and
execute an optional program before the VL IPC initiates the shutdown procedure.
Display
No display
12- and 15-in. display
17- and 19-in. display
1
24-in. display
No display
12-, 15-, 17- and 19-in.
display
24-in. display1
No display
12-, 15-, 17- and 19-in.
display
24-in. display1
Startup and Operation
Power supply
output rating
2.5 A
2.5 A
5 A
10 A
5 A
5 A
10 A
5 A
5 A
10 A
3-31