Figure 3-36 "Ups Selection" Dialog Box; Figure 3-37 "Ups Interface Configuration" Dialog Box - Valueline VL PPC 6015 VW 10 User Manual

Ipc with touch screen
Table of Contents

Advertisement

Valueline IPC
3-34
PHOENIX CONTACT
2.
In the Windows XP Control Panel, double-click the "Power Options" icon and click the
"UPS" tab (not available in Windows 7).
Figure 3-36
"UPS Selection" dialog box
3.
Click the "Select" button and set these options:
In the "Select manufacturer" field, select Generic from the drop-down menu.
In the "Select model" field, select Custom.
In the "On port" field, select either COM1 for the DB-9 connector or COM2 for the power
connector (pins A-B).
Click the "Next" button to proceed to the next screen.
Figure 3-37
"UPS Interface Configuration" dialog box
4.
Click the "Power Fail/On Battery" check box and click the "Positive" radio button.
5.
Click the "Low Battery" and "UPS Shutdown" check boxes if those functions are
connected using the DB-9 serial port connector. Do not click these check boxes if the
power connector method is used.
2637_en_D