NEXA MODULAR GB2 VIDEO DOOR ENTRY SYSTEM KIT - VILLAS
WIRING DIAGRAMS:
Video door entry system with 4 access panels, DP-GB2A distributor for door panels and Golmar DC lock
release.
SW1
ON
1
2
3
4
5
6
_
+
AP-
AP+
C1 NA1
Relay 1
12Vdc
(1)
Lock release
max. 12 Vdc/270mA.
SW1
ON
1
2
3
4
5
6
_
+
C1 NA1
AP-
AP+
Relay 1
12Vdc
(1)
Lock release
max. 12 Vdc/270mA.
Important: For AC lock releases or a second lock release, see diagram 'Connection of Golmar AC and DC lock releases' on p. 19.
(1)
Mains
100~240Vac
N
L
L
CN
FA-
GB /A
Access panel
4
or
C2 AP+ AP- P1 P2 BUSBUS
NA2
Relay 2
(1)
AP
Access panel
1
or
NA2
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
(1)
AP
House with distributors
House without distributors (up to 4 monitors)
2
BUS (M) BUS(PL)
( )
*
( )
*
BUS
BUS
DP-
GB A
2
BUS
D
BUS
C
B
A
SW1
ON
1
2
3
_
+
C1 NA1
Relay 1
12Vdc
(1)
Lock release
max. 12 Vdc/270mA.
SW1
ON
1
2
3
_
+
C1 NA1
Relay 1
12Vdc
(1)
Lock release
max. 12 Vdc/270mA.
Important: (in this distributor).
House with distributors:
Leave the end of line in the OFF position.
House without distributors (up to 4 monitors):
Set the end of line to ON.
Access panel
or
4
5
6
AP-
AP+
C2 AP+ AP- P1 P2 BUSBUS
NA2
Relay 2
(1)
AP
Access panel
or
4
5
6
AP-
AP+
NA2
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
(1)
AP
18
3
2
Need help?
Do you have a question about the GB2 Nexa Modular and is the answer not in the manual?
Questions and answers