Specific Objects - GE 469 Communications Manual

Motor management relay
Hide thumbs Also See for 469:
Table of Contents

Advertisement

COMMUNICATIONS GUIDE
Attribute
01h
02h
03h
04h
05h
06h
07h

469 Specific Objects

Attribute
1
469 MOTOR MANAGEMENT RELAY – COMMUNICATIONS GUIDE
Table 23: Acknowledge handler object, Class code 2Bh, Instance 01h, Attributes:
Name/Description
Acknowledge timer. The time
to wait for an acknowledge
before re-sending.
Retry limit. This is the number
of acknowledge time-outs to
wait before informing the
application of a
retry_limit_reached event
COS producing connection
instance. This is the
connection instance which
contains the oath of the
producing I/O application
object which will be notified
of acknowledge handle
events.
ACK list size. This is the
maximum number of
members in the acknowledge
list.
0 = dynamic.
ACK list. List of active
connection instances which
are receiving acknowledges.
Data with ACK path list size.
Maximum number of
members in data with
acknowledge path list.
0 = dynamic.
Data with ACK path list. List of
connection instance /
consuming application object
pairs. This attribute is used to
forward data received with
acknowledgement.
I/O Data Input Mapping Object (class code A0h)
The class and instance attributes for the I/O data input mapping object (class code A0h)
are as follows:
Table 24: I/O data input mapping object, Class code A0h, Attributes:
Name/Description
Revision of the I/O data input
mapping handler object.
Services
Default, Min, Max
Get_Attribute_Single
16, 1, 65535
Get_Attribute_Single
1, 0, 255
Get_Attribute_Single
N/A
Get_Attribute_Single
Get_Attribute_Single
N/A
Get_Attribute_Single
Get_Attribute_Single
N/A
Services
Get_Attribute_All
DEVICENET PROTOCOL
Data type
UINT
USINT
UINT
Byte array of
USINT
Byte array of
UINT, USINT;
Array of USINT
Default, Min, Max
Data type
1, 1, 1
UINT
131

Hide quick links: