Standard Mode
142
. . . . . . . . The mode selector switch S4 was at the 'on'
position when the supply voltage for the termi-
nal was switched on. The Flash data will be re-
tained if the following instructions are complied
with. Switch the terminal off, set S4 to 'off' posi-
tion, switch terminal on - data will be retained
and the terminal will function as before. If S4 is
set to the off-position while power is on - data
will be lost, terminal switches to the download
mode!
. . . . . . . . The version of the programming system and
the operating software of the terminal do not
match. This error occurs if the wrong operating
system version was selected for compilation of
the user description. The two program versions
must match.
. . . . . . . . The protocol driver loaded via the program-
ming system and the terminal's operating sys-
tem do not match. The two program versions
must match.
. . . . . . . . The parameters of SER1 were modified. To
achieve an operational connection, both com-
munication partners must be set to the new
parameters. This message is used for informa-
tional purposes if the connection to the commu-
nication partner can not be established.
. . . . . . . . The operating system can not find a protocol
driver in the user description loaded into the
terminal. Select a protocol, recompile the user
description and activate another download.
. . . . . . . . The protocol selected in the programming sys-
tem when creating the user description and the
terminal hardware are not compatible. For ex-
ample, the Interbus-S protocol driver has been
loaded to a device with standard interfaces.
Section 4-9