Flagro FVNP-200RC Operating Instructions Manual page 3

Indirect fired space heaters
Table of Contents

Advertisement

This heater is designed and approved for use as a
construction heater under Standard ANSI Z83.7/
CGA 2.14. 2000.
We cannot anticipate every use which may be made
of our heaters. CHECK WITH YOU LOCAL FIRE
SAFETY AUTHORITY IF YOU HAVE QUESTIONS
ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat
producing products in specific applications. Your local
authority can advise you about these.
Model .................................................................
Input Range................................................. ........
Fuel ...................................................................
Manifold Pressure .................................................
Maximum Inlet Pressure .......................................
Electrical ............................................................
Ignition ...............................................................
................................................................
Air Circulation .......................................................
Fuel Consumption ..................................................
Approved ..............................................................
SPECIFICATIONS
- 3 -
FVNP-200RC
200,000 btuh
Propane
Natural Gas
1.45" W.C. Propane
3.44" W.C. NG
13" W.C. Propane
10" W.C. NG
115V 15 AMP
Direct Spark Ignition
Thermostat Control
2600 cfm
9.25 lbs/hr Propane
190 cfh NG
cETLus listed

Advertisement

Table of Contents
loading

Table of Contents