Precautions during assembly
• Pass the cable through the hole of the cable for
the right-side plate in advance.
• There are two types of dampers: the one whose
outside color is white is for the left-side plate,
and the one whose outside color is black is for
the right-side plate.
If you make a mistake in this assembly, the
upper unit will not open or close properly.
• Since the tips of the screws that mount the
damper will protrude inward, use the screws
with round-shaped tips to prevent injuries.
• With the upper unit closed and locked, install
the damper and check that it engages the rack
correctly.
• Install the leaf spring and the stopper at the end
of the assembly, with the upper unit closed.