CHAPTER 3 DISASSEMBLY & REASSEMBLY
7. Ultrasonic sensor PCB (lower side)
1)
Detach the right/left cover assembly.
2)
Unhook the connector on the main CPU PCB,
which is connected to the cable
two screws
(one on each side).
Cable
Screw
Fig. 3-511
3 - 42
3)
Pull off the ultrasonic sensor PCB (with metal
plates)
. Remove
Ultrasonic sensor PCB (with metal plates)
Precautions during the assembly
• Match the positioning marks
side, tighten the right-side screw while holding
the left side, and then tighten the screw on the
left side.
Positioning mark
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
from the right.
Fig. 3-512
on the right
Fig. 3-513