I.
SELECTION OF
LOCATION
It is recommended that the customer engineer
personally inspect the customer's premises before
installing this machine. The location should meet
the following requirements:
The power supply should be connected to an
outlet capable of supplying the voltage shown
on the rating plate plus or minus 10%. A
grounded plug must be used.
Grounding Items
1)
Power outlet grounding terminal
2)
Earth lead that has been grounded for
office equipment
The machine should not be installed on
unstable places such as a fragile table or
inclined surface. The weight of the machine is
approx. 23 Kg.
Ambient temperature and humidity should be
10 to 32.5ºC and 20 to 80% RH. However,
since the performance-guaranteed ambient
conditions are 15 to 27.5ºC and 25 to 75% RH,
it is desirable for the machine to be operated
under such conditions.
In particular, do not install the machine near
water faucets, humidifiers, hot water heaters,
and refrigerators.
COPYRIGHT © 2003 CANON ELECTRONICS INC. CANON DR-6080/9080C FIRST EDITION OCT. 2003
CHAPTER 4 INSTALLATION & MAINTENANCE
The machine should not be exposed to open
flame, dust, ammonia or other corrosive gases,
direct sunlight, intense vibration, or near unitry
that generates electromagnetic waves.
* Prevent cigarette smoke from coming into
contact with the machine.
* In applications where installation in areas
receiving direct sunlight is unavoidable, a
heavy curtain should be installed on the
windows to protect the machine.
Maintain sufficient space around the machine
during operation and maintenance, and to allow
proper ventilation.
* The exhaust fan and power cord are located
at the rear of the machine. Do not push the
machine against the wall.
* Allow sufficient space on both sides of the
machine so that you can insert your hands to
lift it when the machine is to be moved.
100 mm or more
100 mm
or more
630 mm
or more
660 mm or more
Fig. 4-101
100 mm
or more
810 mm
or more