Store Data; Determine A Sound Source Among Two - Kimo DB 200 User Manual

Sound level meter
Table of Contents

Advertisement

The measure will stop by itself after time T previously chosen for the measurement of the S1 source.
The equivalent continuous level calculated from the two combined sources is displayed in front of 'S1 + S2'.

5.5.3 Store data

At the end of the measurement a screen of all results is displayed. It is then possible to :
➢ Accept measurements and store them : move the cursor on Sto. and press once on OK key to confirm. A banner displays the
storage phase.
S1
calculation
➢ Reject measurements and not store them : move the cursor on RST and press twice on OK key to confirm. A banner displays
the phase of data deletion.
S1 + S2
results

5.6 Determine a sound source among two

The determination of a sound source among a set of two can not run unless the operator can interrupt one of the
two sources, the aim being to estimate the sound level of a source without the presence of the other source.
Example : outdoor heat pump in a background noise of day.
Estimate the sound level of a heat pump without the background noise of day, to estimate the possible nuisance of the heat pump in a
noise environment less noisy as the one present the night.
Make some measurements
S2
calculation
RST active
S1 + S2
results
Storage
Deletion
18

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DB 200 and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF