Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP 200 P and is the answer not in the manual?

Questions and answers

Summary of Contents for Kimo MP 200 P

  • Page 1 actoolsupply.com actoolsupply.com MP 200 Supplied Calibration with Manometer certificate actoolsupply.com...
  • Page 2 Kimo MP 200 P Thermo Anemometer Manometer Kimo MP 200 M Thermo Anemometer Manometer Kimo MP 200 G Thermo Anemometer Manometer Kimo MP 200 H Thermo Anemometer Manometer Kimo MP 200 HG Thermo Anemometer Manometer actoolsupply.com...
  • Page 3: Table Of Contents

    actoolsupply.com Table of contents I – Technical specifications.....................4 Technical features..........................4 Specifications............................4 II – Introduction........................5 Description..............................5 Connections..............................6 III – Browsing........................7 IV –Menus..........................8 Probe menu...............................8 Functions..............................8 Pressure................................8 Airflow..................................8 Area..................................8 Duct type................................8 Sizes..................................8 K2 Factor................................9 Units..................................9 COmax..................................9 Air velocity................................9 Hold - Min/Max............................9 Calculation..............................9 Point / point average............................9 Automatic average............................9 Automatic point / point average........................10...
  • Page 4: I - Technical Specifications

    actoolsupply.com I – Technical specifications Technical features Pressure module Housing....ABS shock-proof IP54 Piezoresistive sensor Keypad....Metal-coated, 5 keypads, 1 joystick Overpressure allowed ±500 Pa : 250 mbar Conformity..... Electromagnetic compatibility Overpressure allowed ±2,500 Pa : 500 mbar (as per NF EN 61326-1) Overpressure allowed ±10.000 Pa : 1,200 mbar Power supply ..
  • Page 5: Introduction

    C1 Hour connector connector Value Side view Unit Power supply connection Circular USB port for menu KIMO cable Elastomer grip Keypad Access keys for circular menu Browsing joystick : 4 directions ● Validation ● Escape key On/Off key actoolsupply.com...
  • Page 6: Connections

    actoolsupply.com II – Introduction Connections Interchangeable measurement module Interchangeable modules with Smart-plus system are automatically recognized when connected to the instrument. 1. Current / Voltage module 3. Air velocity with Pitot tube : Pressure module + Pitot tupe (optionnal) It allows current or voltage measurements on V/ A1 or VA/2 channels with current/voltage input cables or ammeter clamps.
  • Page 7: Browsing

    actoolsupply.com III – Browsing Power-up Enter key code with directional pad. (if the locking is activated)   e Homepage display Select a sub menu with access keys Probe Infos Params   or with arrow keys Probe connection Probe display ...
  • Page 8: Menus

    actoolsupply.com IV – Menus Probe menu Wire probes and modules with Smart-plus system are automatically recognized from first connection. The ''Probe'' menu only appears when probes or module are connected. This menu allows to view probe Probe display information plugged to C2, Module, C1 or wireless connections. (See « Connections »...
  • Page 9: K2 Factor

    actoolsupply.com IV – Menus • K2 factor Press  or OK to enter into the K2 factor sub function. Select respectively ON or OFF with  and  in order to enable or disable this function. Confirm with OK . •...
  • Page 10: Automatic Point/Point Average

    actoolsupply.com IV – Menus • Automatic point/point average This function allows to calculate the average value of various points, calculated themselves on a duration beforehand defined. You must enter duration : click on the Period icon. Select minutes or seconds with arrow buttons  and  . Scroll digits with...
  • Page 11: Recording

    actoolsupply.com IV – Menus Recording The Recording menu allows a measurement dataset. You can choose between a planned or a continuous dataset. Memory capacity of the instrument is up to 8,000 points or 50 datasets. 1. Create or launch a continuous dataset Select dataset A continuous dataset can be carried out using MP200 and is composed of several dated measuring points.
  • Page 12: Parameters

    actoolsupply.com IV – Menus 3. Preview of tables of points of datasets Dataset summary You can display tables of points of datasets performed on the device. a. Go to Recording menu. b. Select Display. Click on OK to validate. c. Select dataset name with arrow keys  et . Click on OK to validate. Summary screen of selected dataset is displayed From this screen, you can : Select other dataset using arrow keys t and u.
  • Page 13: Rf Logging

    actoolsupply.com IV – Menus • RF logging This sub-function allows to enable or disable the RF Logging. Click on OK or  to enter into the sub function. Select respectively ON or OFF with  and  in order to enable or disable this function. Confirm wih OK.
  • Page 14: Maintenance

    V – General informations Maintenance KIMO performs calibration, adjustment and maintenance of all your instruments to guarantee a constant level of quality of your measurements. In regards of Quality insurance norms, we recommend that the instruments are checked once a year.
  • Page 15 actoolsupply.com actoolsupply.com...
  • Page 16 Once returned to KIMO, required waste collection will be assured in the respect of the environment in accordance to 2002/96/CE guidelines relating to WEEE. actoolsupply.com...