Installation Plan Gs 630 - Winterhalter GS630 Manual

Utensil washer
Table of Contents

Advertisement

18 Installation plan GS 630

* Considering the local conditions, the exact dimensions
must be determined.
For the dimensions of the machine, see page 46.
TWw / TWk
Water connection (G ¾", external thread)
Position:
Water quality
Water inlet temperature:
Water hardness:
Flow pressure:
Flow rate:
Supply hose:
A
Waste water connection:
Position:
Construction:
Drain pipe:
EZ
Electrical connection
Position:
Construction:
Protection:
Electrical supply pipe:
appr. 400 mm above finished floor
Drinking water in accordance with the Drinking Water Ordinance
TWw: max. 60°C
TWk: Cold water in machines with cold water pre-wash
 3 °dH / 3.8 °e / 0.54 mmol/l
TWw: 100-600 kPa; (1.0-6.0 bar)
TWk: 250-600 kPa; (2.5-6.0 bar) in machines with cold water pre-wash
measured after a possibly upstream water treatment unit
TWw: min. 4 l/min
TWk: min. 15 l/min in machines with cold water pre-wash
included in delivery of the machine
The direct connection without protection fitting is allowed
max. 600 mm above finished floor
with siphon
1500 mm long (standard)
appr. 300 mm above finished floor
Wall outlet for machines without power cord
Mains socket for machines with power cord
Mains disconnector with all-pole mains disconnection
and min. 3 mm contact opening width
Residual-current circuit breaker
depends on the total connected load of the machine (see page 48)
3000 mm long; cross-section: 5 x 2.5 mm
3000 mm long with power cord (Option); cross-section: 5 x 2.5 mm
3000 mm long; cross-section: 4 x 4.0 mm
English
Installation plan GS 630
Important!
Provide the local connections on the left or
the right beside the machine.
Observe both the local and country-specific
regulations when conducting electrical and
hydraulic connection work.
Only when the local mains disconnector is
switched off, the machine is without power.
Now bond the machine equipotentially.
Electrical supply pipe (Type H07 RN-F)
If the mains connecting line of this device is
damaged, it must be replaced by the
manufacturer or his Customer Service or
another qualified person in order to prevent
hazards.
Supply hose
Old existing hoses may not be re-used.
The supply hose may not be shortened or
damaged.
2
(16A; 3 N~)
2
(20A, 25A; 3~)
2
(16A; 3 N~)
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents