Grounding The Device; Cabling Recommendations - RuggedCom RSG2488 Installation Manual

Fully managed, industrial ethernet switch
Hide thumbs Also See for RSG2488:
Table of Contents

Advertisement

RUGGEDCOM RSG2488
Installation Guide
Figure 14: Failsafe Alarm Relay Wiring
1. Normally Open
2. Common
Control of the failsafe relay output is configurable through the Rugged Operating System (ROS) software. One
common application for this relay is to signal an alarm if a power failure.
Section 2.4

Grounding the Device

The RSG2488 chassis ground connection uses a #6-32 screw. It is recommended to terminate the ground
connection with a #6 ring or spade lug and torque it to 1.7 Nm (15 lbf-in).
Figure 15: Chassis Ground Connection
1. #6-32 Screw
2. Stainless Steel Standoff
Section 2.5

Cabling Recommendations

Before connecting the device, be aware of the recommendations and considerations outlined in the following
sections:
Section 2.5.1, "Protection On Twisted-Pair Data Ports"
Grounding the Device
3. Normally Closed
1
3. #6 Ring Lug
2
1
3
Chapter 2
Installing the Device