Page 3
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol.
Connecting AC or DC Power ................16 2.6.2 Connecting External PoE Power ................17 2.6.3 Wiring Examples ....................19 Device Management ......................23 Connecting to the Device ..................23 Configuring the Device ..................24 RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Page 5
European Union (EU) ..................42 6.1.4 FCC ........................42 6.1.5 FDA/CDRH ......................43 6.1.6 ISED ........................43 6.1.7 ISO ........................43 6.1.8 RoHS ........................43 6.1.9 Other Approvals ....................44 EMC and Environmental Type Tests ..............44 RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Preface This guide describes the RUGGEDCOM RS416PF. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device. It is also recommended for use by network and system planners, system programmers, and line technicians.
Preface Supplementary documentation Supplementary documentation Documentation related to RUGGEDCOM RS416PF is available on the Siemens Industry Online Support website at https://support.industry.siemens.com/cs/ww/en/ps/15414. For specific documents, search the following: • Product notes https://support.industry.siemens.com/cs/ww/en/ps/15414/pm • Manuals https://support.industry.siemens.com/cs/ww/en/ps/15414/man • FAQs https://support.industry.siemens.com/cs/ww/en/ps/15414/faq Application examples •...
Siemens to provide training specific to the customer's application. For more information about training services and course availability, visit https:// www.siemens.com or contact a Siemens Sales representative. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
The RUGGEDCOM RS416PF also features a wide operating temperature range of -40 to 85 °C (-40 to 185 °F) allowing it to be installed in virtually any location.
CSA/UL 62368-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS416PF features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
Page 12
Figure 1.1 RUGGEDCOM RS416PF Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM RS416PF operating system are described in "Communication Ports" (Page 25). Port Status Indicator LEDs Port status indicator LEDs indicate the operational status of each port, dependent on the currently selected mode.
"Connecting to the Device" (Page 23). Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS416PF: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
Note the different national regulations. Cabling Recommendations All copper Ethernet ports on RUGGEDCOM products include transient suppression circuitry to protect against damage from electrical transients and conform with IEC 61850-3 and IEEE 1613 Class 1 standards. This means that during a transient electrical event, communications errors or interruptions may occur, but recovery is automatic.
For more information about the BNC ports, refer to "BNC Ports" (Page 31). 1.6.1 Supported Time Synchronization Sources The following time synchronization sources are supported by the RUGGEDCOM RS416PF, with or without the PTP card: Synchronization Source Without PTP Card With PTP Card ü...
GPS receiver at each node or for which GPS signals are inaccessible. The RUGGEDCOM RS416PF only supports ordinary clock mode. An ordinary clock can be configured as either a Grandmaster Clock (GM) or a Slave Clock (SC) within the master-slave hierarchy.
(VL) the connected devices see is greater than the minimum required voltage. 1.6.3 IEEE 1588 Support RUGGEDCOM RS416PF supports various IEEE 1588 time synchronization capabilities and provides synchronization in 2-step mode. This mode supports the following clock types: •...
The surface of the device may be hot during operation, or as a result of the ambient air temperature. Wear appropriate personal protective equipment and use caution when working with or around the device. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
For more information, refer to "Connecting Power" (Page 15). Connect the device to the network. For more information, refer to "Communication Ports" (Page 25). Configure the device. For more information, refer to "Configuring the Device" (Page 24). RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RS416PF can be equipped with rack mount adapters pre-installed at the front or rear of the chassis. Additional adapters are provided to further secure the device in high-vibration or seismically active locations.
2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS416PF can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS416PF can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
Control of the failsafe relay output is configurable through RUGGEDCOM RS416PF. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the "RUGGEDCOM RS416PF User Guide" for the RUGGEDCOM RS416PF.
Chassis Ground Connection Connecting Power The RUGGEDCOM RS416PF supports a single high AC or low DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RS416PF can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power module and PoE ports.
3. Use these screws along with #6 ring tongues to secure the wires to the terminal block. Note For wiring options, refer to "Wiring Examples" (Page 19). Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Make sure the supplied terminal block cover is always installed before the device is powered. Install the terminal block cover. 2.6.2 Connecting External PoE Power The RUGGEDCOM RS416PF supports up to four 10/100Base-TX Power-over-Ethernet (POE) Ports that require power from an external source. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Page 27
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to "RUGGEDCOM...
Make sure the supplied terminal block cover is always installed before the device is powered. Install the terminal block cover. 2.6.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 2.8 Single AC Power Supply RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Page 29
Installing Device 2.6.3 Wiring Examples Figure 2.9 Single DC Power Supply Figure 2.10 DC Power Supply and External PoE Power Supply RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Page 30
Installing Device 2.6.3 Wiring Examples Figure 2.11 AC Power Supply and External PoE Power Supply RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS416PF console and Web interfaces on the device. For more detailed instructions, refer to the "RUGGEDCOM RS416PF User Guide"...
Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS416PF console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports" (Page 25).
Communication Ports The RUGGEDCOM RS416PF can be equipped with various types of communication ports to enhance its abilities and performance. Each communication port type has a specific place in the RUGGEDCOM RS416PF chassis. Slot 1 Slot 2 Slot 3 Slot 4...
Port Specifications" (Page 36). PoE Ports The RUGGEDCOM RS416PF supports up to four 10/100Base-TX Power over Ethernet (POE) ports powered by an external power supply. Each port complies with the IEEE 802.3af standard and features auto-sensing and automatic power off when cables are removed.
60 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM RS416PF operating system to disable low priority ports when demand is too high. Ports can also be enabled/disabled and placed on a power schedule to conserve power.
For specifications on the available fiber optic Ethernet ports, refer to "Fiber Optic Ethernet Port Specifications" (Page 36). Serial Ports The RUGGEDCOM RS416PF supports serial cards with fiber serial ST (Straight Tip) connectors, RS232/RS485/RS422 DB9 serial ports or RS232/RS485/RS422 RJ45 serial ports.
Page 38
Pins 1, 4 and 6 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform hardware flow control. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Page 39
Pins 1, 2 and 3 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform hardware flow control. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
TTL IN Port Figure 4.13 PTP Module Inputs are controlled by RUGGEDCOM RS416PF and only one can be active at any time. For information about activating an input, refer to the "RUGGEDCOM RS416PF User Guide" for the RUGGEDCOM RS416PF. The color of the Sync LED on the front panel of the PTP module indicates the status of the incoming timing signal: •...
• The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring. 120Ω 10nF 120Ω 10nF RUGGEDCOM RS416PF Common (Isolated Ground) Negative Positive Shield to Earth (Connected At a Single Point) RUGGEDCOM RS416PF...
The HI power supply is the same power supply for both AC and DC. PoE Power Supply Specifications Power Input Range Internal Maximum Power Supply Type Fuse Rating Consumption Minimum Maximum 48 VDC 37 VDC 72 VDC 2 A(T) 68 W (T) denotes time-delay fuse. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Shielded or unshielded. Auto-crossover and auto-polarity. RMS 1 minute. Fiber Optic Ethernet Port Specifications The following details specifications for the fiber optic Ethernet ports that can be equipped on the RUGGEDCOM RS416PF. 10Base-FL Ethernet Optical Ports Power Connector Cable Tx λ...
9/125 1300 9/125 1300 9/125 1300 Typical. Serial Port Specifications This section details specifications for ports that can be equipped on the RUGGEDCOM RS416PF. Copper Serial Ports Baud Rate Connector Isolation 1200 to 230400 kbps 2.5 kV 1200 to 230400 kbps RJ45 2.5 kV...
100 mA Output Voltage (V TTL-Compatible Output Impedance (R 50 Ω Operating Environment The RUGGEDCOM RS416PF is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
Certification The RUGGEDCOM RS416PF device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. Approvals This section details the standards to which the RUGGEDCOM RS416PF complies. Note All relevant certificates and test reports are available on...
Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
China RoHS (relating to SJ/T 11364) • Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Declarations of conformity for each directive are available online via Siemens Industry Online Support [https://support.industry.siemens.com/]>. RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
• IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EMC and Environmental Type Tests The RUGGEDCOM RS416PF has passed the following EMC and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels...
Page 54
Siemens specified severity level. IEEE 1613 EMC Immunity Type Tests Note RUGGEDCOM products meet Class 1 requirements for copper Ethernet configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
Page 55
Test Db 95% (non- Heat, Cyclic) condensing), 55 °C (131 °F), 96 hours IEC 60068-2-6 Vibration 2 g @ 10-150 Hz Class 2 IEC 60068-2-27 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RS416PF Equipment Manual, 10/2023, C79000-G8976-1355-07...
Need help?
Do you have a question about the SIMATIC NET RS416PF and is the answer not in the manual?