Wiring Power Supply Terminal Blocks - RuggedCom RSG2488 Installation Manual

Fully managed, industrial ethernet switch
Hide thumbs Also See for RSG2488:
Table of Contents

Advertisement

Chapter 2
Installing the Device
1.
Make sure power to the device has been disconnected and wait approximately two minutes for any
remaining energy to dissipate.
2.
Unscrew the power supply(ies) from the chassis.
3.
Pull the power supply(ies) from the chassis.
1
Figure 6:
1. Screws
2. Power Supply
4.
Install a cover(s) over the empy slot to prevent the ingress of dust and dirt.
Section 2.2.3

Wiring Power Supply Terminal Blocks

The RSG2488 can be equipped with screw-type or insulated terminal blocks for high or low AC/DC power input.
Connect the terminal blocks to the HI and LO terminal ports on the rear face of the device.
Figure 7: Terminal Ports
1. LO Input
2. HI/HIP Input
NOTE
The screw-type terminal block is installed using Philips screws and compression plates, allowing either
bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable screws, which
must be removed to make connections.
8
2
3. Slot
1
3
2
Wiring Power Supply Terminal Blocks
RUGGEDCOM RSG2488
Installation Guide