Service guide
3.
Disassembling the
pressure exchanger
4
Disassembling and assembling iSave 21
1.
Unscrew the bolts in the flange.
3.
Gently push out the flange.
5.
Unscrew the bolts in the flange.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
2.
Screw in the two M8 bolts.
4.
Wet the shaft and shaft seal with clean
filtered water. Gently lever the shaft
assembly free using 2 screwdrivers.
6.
Gently remove the flange.
Note: Loose parts on the inside of the flange.