3.1
Measurement Range: 1 to 50A
Accuracy: 1 to 50A
Output Signal: 10mV/A
Load Impedance: >100kΩ/100pF
Insertion Impedance: 0.39mΩ @ 50Hz, 58mΩ @1000Hz
Working Voltage: 600Vrms
Common Mode Voltage: 600Vrms
Influence of Adjacent Conductor:
< 10mA/A at 50Hz at 23mm from the probe
Influence of Conductor in Jaw Opening: 0.5% reading
Power Source: Powered by Micro-Ohmmeter Model 6292
3.2
Jaw Opening: 1.2" (31mm)
Maximum Cable Diameter: One 1.18" (30mm) or two 0.95" (24mm) or
two bus bars 1.2 x 0.4" (31.5 x 10mm)
Dimensions: 8.8 x 3.82 x 1.73" (224 x 97 x 44mm)
Weight: 15 oz (440g)
Output: 4-conductor shielded cable with 5-pin XLR connector
Zero Adjustment: Automatic zero by Model 6292
Case Protection: IP30 per IEC 529
Drop Test: 1.0m on 38mm of oak on concrete; test according to EN 61010