8. Wall Control Installation
3-WAY INSTALLATION
(One fan controlled by two different SW406 wall
controls) (See Figures 33 and 34.)

WARNING

!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
8.10
Disconnect electrical power to the branch circuit at the
circuit breaker or fuse box before attempting to install
the ceiling fan SW406 Wall Control into the Outlet Box.
WARNING
!
Do not connect any neutral (white) wire to this control.
Incorrect wiring will damage this control.
8.11
At all wall box locations remove faceplates and screws
from existing controls. Pull controls out from wall boxes
and determine which wall box contains the "Hot" Wire
and which wall box contains the "Load" Wire.
Also, identify traveler wires which are common to both
wall boxes. Disconnect wires from existing controls only.
Do not attempt to disconnect any wires not already
connected to existing controls.
8.12
Before installing the SW406 Wall Control, place the
SW406 Wall Control in "OFF" mode by pushing
"ON/OFF" switch to the "OFF" position.
(Continued)
SW406
FAN/LIGHT
....
HOT
WALL
CONTROL
OFF
GROUND
BLACK
TRAVELER
WIRE
NEUTRAL
RECEIVER LOCATED WITHIN
THE CEILING COVER
8.13
Figure 33
Install the first SW406 Wall Control in the Wall Box
containing the "Hot" Wire. Connect the SW406 Wall
Control Black Wire with the Yellow Label marked
"To Power Supply" to the "Hot" Wire in the Wall Box.
Securely connect the Wires with the Wire Connector
(supplied) (Figure 33).
8.14
Connect the SW406 Wall Control Black Wire with the
Blue Label marked "To Fan" to the Traveler Wire in the
Wall Box. Securely connect the Wires with the Wire
Connector (supplied) (Figure 33).
8.15
Connect the SW406 Green Ground Wire to the Bare
Copper Wire or Green Ground Wire in the Wall Box
Securely connect Wires with Wire Connector (supplied)
(Figure 33).
Please contact 1-800-654-3545 for further assistance
21
SECOND SW406
WALL CONTROL
....
PURCHASED
SEPARATELY
OFF
GROUND
LOAD
BLACK
GROUND
emersonfans.com