5.7

Specifications

Specifications
Program memory
System clock
Analog inputs / outputs
High-speed counters
Interrupt inputs
MemoryCard slots
Serial interfaces
PROFIBUS-DP bus master
DP slaves
DP baud rate
Command processing time
D Bit command
D Word command
D Complex commands
I/O image
Cycle time for 1 k commands
Interrupt response time
Registers
OM organization modules
PB program modules
Nesting depth
Bracket levels
Operand formats
I Inputs
D I: Bit, byte, word
D EI: Byte, word
D Analog
O Outputs
D O: Bit, byte, word
D EO: Byte, word
D Analog
M Markers
T Timers
C Counters
DM Data modules
DF Data fields
S System area
1070 072 145-102 (01.07) GB
ZE200
ZE201
ZE200A
128 kbytes RAM and 128 kbytes Flash-EPROM
No
No
1 x connection for incremental rotary transducer (ROD; not ZE200-DP and ZE200A-DP)
No
1
< 1.0 ms (on ZE201, ZE200-DP, ZE200A-DP longer on rare occasions)
Bit, byte, word, double word for constants
1536 bits, M0.0 through M191.7
Central Processing Unit
ZE200M
ZE200AM
Yes
4/1
No
4/1
2 x 32 bit counters or
3
Yes
2
No
0.3 ms
0.3 to 10 ms
up to 40 ms
0.3 to 1.0 ms
< 0.5 ms
4
19, OB1 through OB19
256, PB0 through PB255
32 modules
7
192 bits, I0.0 through I23.7
128 bytes, EI0 through EI127
4
4
128 bits, O0.0 through O15.7
128 Byte, EO0 through EO127
1
1
128, T0 through T127
64, C0 through C63
256, DM0 through DM255
8 kbytes, DF0 through DF8191
256 bytes, S0 through S255
5–29
ZE200-DP
ZE200A-DP
No
4/1
No
1
1
Yes
max. 64
9.6 kbaud to 12 Mbaud
4
1