Connecting To Profibus-Dp - Bosch CL200 User Manual

Table of Contents

Advertisement

RM2-DP12 Module
16–2
16.2

Connecting to PROFIBUS-DP

Baud Rate
The module uses single modular width.
The RM2-DP is connected to the PROFIBUS by means of a male DB-9 con-
nector which, for security reasons, should be screwed tightly onto the female
DB-9 connector of the RM2-DP12. The X71 PROFIBUS connector is located
on the front panel. The pin assignment corresponds to the PROFIBUS stan-
dard.
Pin assignment, female DB-9 PROFIBUS-DP connector:
Pin
1
2
3
4
5
6
7
8
9
From the P5V_ISO on the X71 PROFIBUS-DP connector, up to 100 mA of
current can be picked off externally.
The module automatically adjusts to the baud rate of the PROFIBUS-DP
(9600 baud to 12 Mbaud).
Signal
Function
not used
not used
B_TLG
RX / TX data P
RTS_SIG
Repeater control signal P
(TTL signal)
GND_ISO
Data reference potential
-pos.
P5V_ISO
E
; 100 mA
not used
A_LTG
RX / TX data N
GND_ISO
Repeater control signal N
(DGND)
1070 072 145-102 (01.07) GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents