7.1 INTRODUCTION

This section provides the manufacturer's advice
on how to install KMDSI accessories including
the hot water shroud, low pressure inflator hoses,
and the weld lens assembly.
7.2 HOT WATER SHROUD INSTALLA-
TION PROCEDURES
The KMDSI Hot Water Shroud Kit only fits
the "B" sideblock. The Hot Water Shroud
(KMDSI Part #525-100) should be used
whenever diving in water colder than 35.6 F
(2 degrees C). The KMDSI hot water kit is
designed to be integrated with a hot water
supply to help maintain breathing gas tem-
perature at an acceptable level for the diver.
In addition the hot water reduces the possi-
bility of ice forming in the demand regulator
or gas train components. Even with water
temperatures of 40 F (4 C) the diver can
experience discomfort and severe heat loss
through the respiration process. For this rea-
son, KMDSI recommends installing the hot
water shroud when diving in waters colder
than 40 F (4 C). Water supply to shroud
assembly should be at least 1 gallon (3.7
liters) per minute at a minimum temperature
of 105 F (42C). When diving operations are
conducted during severe cold surface tem-
peratures a hot water shroud should be used
to prevent ice from developing in and on gas
train components while the diver is on the
surface.
Tools Required:
1/4 inch Flat Blade Attachment on Locking Screw-
driver
7/8 inch Open End Attachment on Torque Wrench
11/16 inch Open End Attachment on Torque
Wrench
Document # 010518001 © Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved.
CHAPTER 7
ACCESSORIES
1) Disconnect the bent tube assembly (119b) at
the side block end only. Loosen the jam nut (61c)
at the regulator. If the bent tube will not swivel,
loosen the large nut at the regulator.
2) Remove the locknut (83), spring (84) and free
flow knob (85).
3) Remove the locknut (102), spring (101) and
auxiliary valve knob (100).
Fig. 7.1 Remove the auxiliary valve and free flow knobs
to install the hot water shroud.
4) Screw the regulator adjustment knob (47) in all
the way.
5) To install the rubber regulator cover, slide it
over the bent tube assembly (119b) and stretch it
over the regulator adjustment knob (47).
Fig. 7.2 Install the regulator cover.
KMB 18 & 28 MANUAL