Fig. 6.41 Removing an O-ring from an "A" regulator hose.
3) Once removed discard, as damage to this O-
ring (118a) is unavoidable. Installation of a new
O-ring is simple. Wipe with a light silicone grease
coating, stretch onto the fitting, and slide until the
O-ring (118a) snaps into the groove.
Document # 010518001 © Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved.
KMB 18 & 28 MANUAL
6.8.3 Hose Replacement (117a)
1) Always install the side block (94a) end first,
and the regulator inlet nipple (61a) end last. Use
a backup wrench on the nipple.
2) Tighten the side block end and tighten the
regulator end.
3) Test for leaks prior to use.
Fig. 6.42 Replacing an "A" regulator hose.
page 71