7-5. THERMAL SENSOR
REPLACEMENT
698
1. Remove electrical power to unit.
Remove electrical power supplied to the unit by
unplugging the unit, or by turning off the wall circuit
breaker, or electrical shock could result.
2. Remove the control side-side panel.
3. Unplug probe from control PC board.
4. Press down on the probe bracket and pull probe from
bracket, or using 3/8" socket, remove nut securing probe
bracket to unit and remove bracket and probe from unit.
5. Remove vent panels from inside. (See Section 3-12.)
6. Install new probe in reverse manner, exposing the probe
½"
1
inside cabinet.
½
1
inch probe position is important. Improper position-
ing will cause erroneous temperature readings.
7. Plug probe onto P2, 2 pin connector.
NOTE