Cleaning or replacing the air filters
- Disconnect the fixture from power. On each side of the head, remove the 2 screws that hold the side cover
using a Torx-20 screwdriver. Slide the cover forward to remove. Lift the filter off of the cover.
2 Clean the filters with a vacuum or compressed air. If they are saturated with smoke residue or other
contaminants, soak them in warm soapy water and blot dry. Replace any filter that is damaged or
impossible to get perfectly clean.
3 Place the filters on the covers and replace the covers.

Software installation

The factory-installed software version is indicated on the serial number label. The currently installed
software version number is displayed in the control panel during power-on and in the
Software updates are released when features are added. The latest MAC 2000 Wash software is available
for download from the Support area of the Martin website at http:77www.martin.com.
ReWuirements
Software can be installed using one of the following hardware devices:
- Martin MP-2 Uploader connected to the fixture via a data link.
2 PC connected to the fixture via a data link using one of the following DMT interface hardware devices:
a Martin DABS -, currently available with the Martin MUM ZMulti Utility Manager[ software package
a ShowDesigner PCI DMT Interface Card Z2048 channel version[
a LightJockey PCI DMT Interface Card Z5-2 and 2048 channel versions[
a LightJockey PCMCIA DMT Interface
a LightJockey 4064 ISA DMT Interface Card ZDJ and Club versions[
Besides one of the hardware devices listed above, the Martin Software Uploader program, version 5.5 or
later, is re_uired. The Software Uploader program is supplied with the MUM and LightJockey programs, as
well as with DABS- and MP-2 hardware devices. It is also available for download from the Support area of
the Martin website at http:77www.martin.com.
Note: If intermediate control systems such as the Martin Lighting Director ZMLD[ and the Martin Matrix are
present, they must be bypassed when updating fixture software via the DMT link. These systems do not
relay the update code correctly because the code is not DMT-compliant.
Standard software installation
For guidance on preparing and using your hardware device and the Software Uploader program, refer to the
user documentation and7or online help for these products.
'hat to do if the standard software installation fails
If the normal upload procedure does not work, or if the software update notes call for a boot sector update,
move the boot sector Xumper at PL-6 to the BOOT position before uploading software.