Emerson EV1000-2S0004G User Manual page 79

General purpose variable speed drive ev1000 series
Hide thumbs Also See for EV1000-2S0004G:
Table of Contents

Advertisement

Sub-function
Data (request)
code
Parameter group
number and
0x0000
index within a
group occupy the
MSB and LSB.
Parameter group
number and
0x0001
index within a
group occupy the
MSBand LSB.
Parameter group
number and
0x0002
index within a
group occupy the
MSBand LSB.
Parameter group
number occupies
0x0003
the MSB and the
LSB is "00".
Parameter group
number occupies
0x0004
the MSB and the
LSB is "00".
Parameter group
number occupies
0x0005
the MSB and the
LSB is "00".
0x0006
0x3300
0x0007
0x3300
The status parameter group cannot be modified nor support
upper or lower limit read-out operation.
Parameter property is 2 bytes in length. The definitions of its
bits are as follows:
Parameter
Value
property (Bit)
000B
010B
Bit2~Bit0
011B
100
Others
Bit3
Reserved
00B
Bit5~Bit4
Others
01B
10B
Bit7~Bit6
11B
00B
Data (respond)
Meaning
Read the
Upper limit of a
upper limit of
parameter.
a parameter
Read the
Lower limit of a
lower limit of a
parameter
parameter
Parameter
Read out
property, see
Parameter
description below
property
Read max.
Max. index within
index within a
a parameter
parameter
group
group
Next parameter
group number
Read next
takes the higher
parameter
byte and lower
group number
byte is "00"."
Last Parameter
Read
group number
previous
occupies the
parameter
MSB and the LSB
group number
is "00".
Read
currently
Currently
displayed
displayed status
status
parameter index
parameter
index
Display next
Next status
status
parameter index
parameter
Meaning
No decimal part
One digit of decimal
Two digits of decimal
Three digits of decimal
Reserved
Modification step is "1"
Reserved
Modifiable
Cannot be modified during running
Set by factory, cannot be modified
Actual parameters, cannot be
modified
EV1000 Series General Purpose Variable Speed Drive User Manual
Appendix 2 Communication Protocol
Parameter
Value
property (Bit)
0000B
0001B
0010B
0011B
0100B
Bit11~Bit8
0101B
0110B
Others
1
Bit12
0
Bit15~Bit13
Reserved
Drive control parameters cover the drive start/stop,
frequency setting, etc. Through the status parameters,
present frequency, output current, output torque, etc. can be
retrieved. The control and status parameters are listed
below:
Table 2 Drive's Control Parameters Index
Register
Parameter name
Address
0x3200
Control command word
0x3201
Main reference freq.
0x3202
Reference Frequency
0x3203
Digital close loop setting
0x3204
Pulse close loop setting
0x3205
Analog output AO1 setting
0x3206
Analog output AO2 setting
0x3207
Digital output DO setting
0x3208
Freq. proportion setting
0x3209
Virtual terminal control setting
0x320A
Acc time 1
0x320B
Dec time 1
Table 3 Inverter Status Parameters Index
Register
Address
0x3300
Operation status word 1
0x3301
Actual value of the current main setting
0x3302
Drive model
0x3303
Drive type
0x3304
Software version
0x3305
Present actual frequency
0x3306
Output current
0x3307
Output voltage
0x3308
Output power
0x3309
Actual rotating speed
0x330A
Actual line speed
0x330B
Analog close loop feedback
0x330C
Bus voltage
0x330D
External counter
0x330E
Output torque
Digital value I/O terminal status:
0x330F
BIT0~14=X1~X8, Y1, Y2, TC, FAN, BRAKE,
FWD, REV
Meaning
No unit
Unit: Hz
Unit: A
Unit: V
Unit: r/min
Unit: m/s
Unit: %
Reserved
Upper limit is active every nibble
Upper limit is active as a whole
word
Save upon
power-off
No
Y
Y
Y
Y
N
N
N
N
N
Y
Y
Parameter Name
77