Emerson EV1000-2S0004G User Manual page 72

General purpose variable speed drive ev1000 series
Hide thumbs Also See for EV1000-2S0004G:
Table of Contents

Advertisement

70
Appendix 1 Parameter Set
Para.
Name
F9.01 Auxiliary freq. setting method
F9.02 Auxiliary reference factor
F9.03 Digital auxiliary ref.
F9.04 Digital auxiliary ref. control
F9.05 Preset freq.adjust mode
Factor for calculating preset
F9.06
freq.
STOP/RESET key's function
F9.07
and keypad lock
F9.08 Reserved
F9.09 Acc/Dec time unit
F9.10 Droop control
F9.11 High usage of bus voltage
F9.12 Zero freq. threashold
F9.13 Zero freq. hysteresis
F9.14 Preset length
F9.15 Actual length
F9.16 Length factor
F9.17 Length calibration
F9.18 Shaft circumference
F9.19 Pulse per revolution
F9.20 Low voltage compensation
Group 9: Enhanced Function
0: No auxiliary freq.
1: Digital setting 1, adjust by ▲ and ▼
2: Digital setting 2, adjust by UP/DN
3: Digital setting 3, set by serial port
4: VCI analog setting
6: terminal pulse setting
8: - CCI analog setting
10: VCI-5
12: PULSE-0.5 × F1.03
Note: it is invalid if it is the same with main freq. setting
method
For the setting of 4~12, it depends on F1.00
0.00~9.99 (only for F9.01=4~12)
0.00~650.0Hz
One's place: save auxiliary freq. at power-off
0: save
Ten's place:
0: maintain the aux. Freq. after stop
1: clear the aix. Freq. after stop
Hundred's place:
0: positive sign
Note: valid when F9.01=1, 2, 3.
0: disabled
1: adjust based on F005
2: adjust based on current freq.
0.0%~200.0%
One's place: STOP/RESET key function
0: valid only in keypad control mode
1: valid in keypad, terminal, serial port mode, to stop the
drive in specified manner
2: to stop the drive in keypad control mode in specified
manner, for other control mode, display E015 fault and coast
to stop
Ten's place: Reserved
Hundred's place: keypad lockup
0: disabled
1: all keys locked
2: all keys locked except STOP/RESET
3: all keys locked except
4: all keys locked except RUN, STOP/RESET
-
0: second
1: minute
0.00~10.00Hz
0: disabled
1: enabled
0.00~650.00Hz
0.00~650.00Hz
0.000 (function disabled) ~65.535 ( km)
0.000~65.535 ( km) (save after power off)
0.001~30.000
0.001~1.000
0.01~100.00 ( cm)
1~9999
0: disabled
1: enabled (low voltage compensation)
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
5: CCI analog setting
7: - VCI analog setting
9: - terminal pulse setting
11: CCI-5
13: Potentiometer
1: not save
1: negative sign
Unit
Default
Modification
1
0
0.01
1.00
0.01
0.00Hz
1
000
1
0
0.1%
100.0%
1
000
-
-
0
0
0.01Hz
0.00Hz
1
1
0.01Hz
0.00Hz
0.01Hz
0.00Hz
0.001 (km) 0.000 ( km)
0.001 ( km) 0.000 ( km)
0.001
1.000
0.001
1.000
0.01 ( cm)
10.00 ( cm)
1
1
1
0
×
-
×
×
×