Emerson EV1000-2S0004G User Manual page 70

General purpose variable speed drive ev1000 series
Hide thumbs Also See for EV1000-2S0004G:
Table of Contents

Advertisement

68
Appendix 1 Parameter Set
Para.
F7.29
Analog output range
F7.30
AO1 output gain
F7.31
AO2 output gain
F7.32
Y2 max. pulse freq.
F7.33
Preset counting value
F7.34
Specified counting value
Positive or negative logic of
F7.35
terminal
Para.
Name
F8.00
Accumulated length
LED displayed
F8.01
parameter selection
1
LED displayed
F8.02
parameter selection
2
Group 7: Multi-function Terminals
Name
One's place of F7.29: AO1 bias
0: 0~10V or 0~20mA
1: 2~10V or 4~20mA
Ten's place of F7.29: AO2 bias
0: 0~10V or 0~20mA
1: 2~10V or 4~20mA
0.0~200.0%
0.0~200.0%
0.1~50.0 kHz
F7.34~9999
0~F7.33
Positive logic: Xi connects with common terminal is valid,
otherwise invalid.
Negative logic: Xi connects with common terminal is
invalid, otherwise valid.
One's place of F7.35:
BIT0~BIT3: X1~X4
One's place of F7.35:
BIT0: X5
BIT1~BIT3: Reserved
Hundred's place of F7.35:
BIT0~BIT1: FWD, REV
BIT2~BIT3: Y1, Y2
Group 8: Display Control Parameters
0~999.9km
Note: This parameter can be viewed or cleared only.
Binary code implication:
0: not displayed
1: displayed
One's place
BIT0: output freq. (Hz) (before compensation)
BIT1: output freq. (Hz) (after compensation)
BIT2: refrerence freq. (Hz indicator blink)
BIT3: output current (A)
Ten's place
BIT0: rotating speed (r/min)
BIT1: preset rotating speed (r/min indicator blink)
BIT2: actual line speed (m/s)
BIT3: preset line speed (m/s indicator blink)
Hundred's place:
BIT0: output power
Note: if the setting is 0, the default display is operating freq. before
compensation.
Binary code implication:
0: not displayed
1: displayed
One's place
BIT0: output voltage (V)
BIT2: VCI (V)
Hundred's place
BIT0: analog close-loop feedback (%)
BIT1: Analog close-loop setup (%blink)
BIT2: external counter value (no unit)
BIT3: terminal status (no unit)
Hundred's place:
BIT0: actual length
BIT1: preset length
BIT2: accumulated length
EV1000 Series General Purpose Variable Speed Drive User Manual
Range
Range
BIT1: output torque (%)
BIT1: bus voltage
BIT3: CCI ( V)
Unit
Default
Modification
1
00
0.1%
100.0%
0.1%
100.0%
0.1
10.0k
1
0
1
0
1
000
Unit
Default
Modification
0.1km
0
1
3FF
1
000

Hide quick links:

Advertisement

Table of Contents
loading